TDS Mini Controller (0.00 to 19.99 ppm)
$229.99The BL983321 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) of a process stream that is within the 0.00 to 19.99 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower TDS water to flow into a tank being monitored in order to lower its TDS. The BL983321 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. *The BL983321 uses a 0.5 conversion factor in which 1.00 μS/cm = 0.50 ppm.
- Multicolor LED Indicator
- Fire Retardant Casing
- Fire Retardant Casing
Thank you for your interest in our products. A representative will contact you within the next business day.
Adjustable Dry Contact Dosing Relay
The BL983321 features a dosing relay that is activated when the reading is above a user programmable set point.
Programmable Overdose Protection
For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.
Relay Control Override
With the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.
Multicolor LED Indicator
Multicolor LED indicator allows an operator to quickly check the status of the controller.
- Green = Meter in measurement mode and reading is below the set point.
- Orange/Yellow = Reading is above the set point and the relay is activated.
- Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.
Fuse Protected Dosing Contacts
The relay dosing contact is rated for up to a 2A load and is fuse protected.
Labeled Termination Connections
Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.
1/2" NPT Male Threaded Amperometric Probe for Mounting In-line*
The BL983321 mini controller uses the HI7634-00 conductivity probe that is available with different cable lengths.
*HI7634-00 is not included and must be ordered separately
Front ViewInstallation cut-out dimensions are provided as well as outside panel dimensions. |
Side ViewAdjustable location brackets allow the controller to slide easily and securely into place. |
Resources
-
Specifications
Specification Name Detail SKU BL983321 TDS Range 0.00 to 19.99 mg/L (ppm) TDS Resolution 0.01 mg/L (ppm) TDS Accuracy (@25°C/77°F) ±2% F.S. TDS Conversion Factor 0.5 Temperature Compensation automatic from 5 to 50°C (41 to 122°F) with ß =2%/ºC Calibration manual, with CAL trimmer Dosing Relay maximum 2A (fuse protected), 250 Vac, 30 VDC Contact close when measure: > setpoint Overtime adjustable, typically from 5 to approximately 30 minutes Power Supply models “-0”: 12 VDC adapter (included) models “-1”: 115/230 VAC; 50/60Hz Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’) Weight models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.) Ordering Information Supplied with mounting brackets, transparent cover and instruction manual. Recommended Probe HI7634-00 EC/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included). - Product Manuals