| Search By Accuracy | ||
| Parameter: | Accuracy: | |
|
|
||
Home > Agriculture > Monitoring Systems
This indicator continuously monitors the three most crucial nutrient parameters in hydroponic, greenhouse and horticultural applications.
At startup, HI 991405-01 performs a self-check to assure proper working condition. The stability indicator and HOLD function lets the user know when to take readings and freezes the reading on display for easy and accurate recording.
This instrument is supplied with a non-clogging double junction pH electrode as well as a rugged conductivity probe that will withstand even the most aggressive environments. The 12 VDC adapter makes these instruments ideal for all continuous monitoring applications.
Order Information:
HI 991405-01 (115V) and HI 991405-02 (230V) is supplied with HI 1293D pH electrode, HI 7630 EC probe (fixed), HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 70030 1288 mS/cm calibration solution sachet, 12 VDC adapter and instructions.
| Range | pH | 0.0 to 14.0 pH |
| EC | 0.00 to 20.00 mS/cm | |
| TDS | 0.00 to 10.00 g/L (ppt) | |
| Temperature | 0.0 to 60.0°C / 32.0 to 122.0°F | |
| Resolution | pH | 0.1 pH |
| EC | 0.01 mS/cm | |
| TDS | 0.01 g/L (ppt) | |
| Temperature | 0.1°C (0.1°F) | |
| Accuracy @ 20°C | pH | ±0.1 pH |
| EC/TDS | ±2% F.S. | |
| Temperature | ±0.5°C (±1°F) | |
| Temperature Compensation |
pH | automatic |
| EC/TDS | automatic with ß adjustable from 0.0 to 2.4%/°C | |
| Calibration | pH | automatic, one or two points with auto-buffer recognition |
| EC/TDS | automatic, one point at 12.88 mS/cm or 6.44 g/L (ppt) | |
| Probes | pH | HI 1293D PEI body, pre-amplified pH electrode with 1/2” NPT pipe thread, DIN connector and 2 m (6.6’) cable (included); |
| EC/TDS | HI 7630 conductivity probe with 1/2” NPT pipe thread and 2 m (6.6’) cable (fixed) | |
| TDS Factor | adjustable from 0.45 to 1.00 | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
| Input Impedance | 1012 Ohm | |
| Power Supply | 12 VDC adapter (included) | |
| Dimensions/Weight | 160 x 105 x 31 mm (6.3 x 4.1 x 1.2) / 190 g (6.7 oz.) |
| Electrodes | |
|---|---|
| HI 1293D | Spare pH Electrode for pH Monitors |
| HI 7630 | Conductivity & TDS Probe for use with HI 983301, HI 983302, HI 991404 and HI 991405 |
| Solutions | |
| HI 70004P | 4.01 pH Buffer Solution, (25) 20 mL |
| HI 70007P | 7.01 pH Buffer Solution (25) 20 mL sachets |
| HI 70010P | 10.01 pH Buffer Solution (25) 20 mL sachets |
| HI 70030P | 12880 µS/cm EC Solution (25) 20 mL Sachets |
| HI 70031P | 1413 µS/cm EC Solution, (25) 20 mL Sachets |
| HI 70032P | 1382 mg/L (ppm) TDS Solution, (25) 20 mL Sachets |
| HI 70038P | 6.44 g/L (ppt) TDS Solution, (25) 20 mL Sachets |
| HI 70442P | 1500 mg/L (ppm) TDS Solution, (25) 20 mL Sachets |
| HI 70300M | Electrode Storage Solution 1 x 230 mL bottle |
| HI 7061M | General Purpose Cleaning Solution 1 x 230 mL bottle |
Like us on facebook