More Views

HI5000STD

Mini Fertigator

$3,500.00

 


The HI5000 Mini Fertigator precisely monitors and controls fertilizer concentrations and pH for small to mid-sized specialized hydroponics and greenhouse applications. The HI5000 is designed to be used with a mixing tank whereby fertilizer recipes can be mixed exactly to the needs of your crop. The system can be equipped to perfectly control the amount of fertilized water distributed to your plants, lowering costs and saving resources.

  • Customize your fertilizer mixtures with up to 4 stock tanks can be utilized for multiple crops and customized blending.
  • Perfect for Hydroponics & Indoor Gardening.
  • Precision nutrient & acid control to professional grower and advanced home grower alike.

Details

HI5000 setup

Customize your fertilizer mixtures

The HI5000 comes equipped with 2 independent nutrient injectors, each with a max capacity up to 200 l/h. Additional injectors can be added to accommodate multiple nutrients.

Control pH accurately.

The HI5000 comes with a separate pH controller and designated pump specifically designed to handle the most aggressive acids.

Customizable and expandable.

Select the controllers, number of pumps and types of probes you wish to use. The system can be designed to your needs and specifications.

The Hanna HI5000 continuously measures the actual EC and pH of the blending tank or trough system and precisely adjusts the concentration of fertilizer and acid or base.

The HI5000 can be equipped with the HI8000 Series Controller allowing you to automate your entire irrigation system. Control pumps, solenoids, for a completely hands free operation.

The HI5000 (when equipped with the HI8000 Controller) has the capability to utilize the AgriCare software which allows you the ability to monitor and control the system remotely.

 

pH

pH Range 0.0 to 14.0 pH
pH Resolution 0.1 pH
pH Accuracy (@25ºC/77ºF) ±0.0546 pH

EC/TDS

EC Range 0.0 to 10.0 mS/cm
EC Resolution 0.1 mS/cm
EC Accuracy ±0.078 mS/cm

Electrical Requirements

Controller Power Requirements 115V/220V; 50Hz/60Hz. 10 Amp, 4 outlet box recommended
Circulator Pump Solenoid Array Power Requirements 208/240, 3 phase, 30 Amp breaker

Plumbing Requirements

Pressure Requirement (PSI) Maintained at fixed pressure between 50 to 65 PSI
Minimum Flow Rate 1.0 GPM
Maximum Flow Rate Approx. 50 GPM
Pipe Type Recommendations Schedule 40 or 80 PVC
Minimum Pipe Diameter Recommendation 1.25 inch

Process Control Meter

Alarm Relay Range Terminals can be configured as normally open or normally closed (isolated output Max. 2A, Max. 240V, resistive load, 1,000,000 strokes). The alarm is activated if pH falls below the setpoint by the userselectable interval (0.0 to 2.0 pH), or conductivity
Dosing Control Proportional Control: Two independent controls: pH from 0.0 to 2.0 and Conductivity (EC) from 0.0 to 2.0 mS/cm with two separate time cycles from 0 to 90 seconds
Dosing Terminals Two sets of independent terminals (115 to 240V, Max.2A, 1,000,000 strokes) are activated whenever pH exceeds the pH setpoint and/or conductivity falls below the EC setpoint
Enclosure Fiber-reinforced, self-extinguishing ABS
Power Supply 110/115V at 50/60Hz
Environment -10 to 50°C (14 to 122°F) max. 95% RH non-condensing
Ordering Information

Reviews: