pH/ORP/ISE and DO Benchtop Meter Starter Kit
$1,399.99Set yourself up for testing success with our pH/ORP/ISE and DO Benchtop Meter Starter Kit (HI6542). There are two options available to choose from, our opdo® kit which includes an opdo® probe or our DO kit which includes a polarographic DO probe. Our high-performing benchtop meter is ready-to-use straight out of the box and is fully equipped with everything you need to test. Includes necessary modules, electrodes, solutions, and more.
- Precise and consistent. Achieve quick, accurate, and repeatable results
- Reliable and efficient. Ensure quality and meet requirements with easy digital record keeping and increased traceability
- Simple and straightforward. Intuitive navigation menus, built-in help guides, and video tutorials make testing hassle-free
Fits seamlessly into any laboratory or industry environment.
Perfect for chemists, researchers, educators, food manufacturers, beverage producers, and metal finishers to name a few.
Thank you for your interest in our products. A representative will contact you within the next business day.
Resources
-
What's included with our
pH/ORP/ISE and opdo® Starter Kit- Multiparameter Modular System (HI6000-01)
- pH/ORP/ISE Module (HI6000-2) (1 pc.)
- DO Module (HI6000-4) (1 pc.)
- Refillable Combination pH Electrode with BNC Connector (HI1131B) (1 pc.)
- Temperature Probe (HI7662-TW) (1 pc.)
- opdo® Probe (HI7641133) (1 pc.)
- pH 4.01 Buffer Solution Sachets (2 pcs.)
- pH 7.01 Buffer Solution Sachets (4 pcs.)
- pH 10.01 Buffer Solution Sachets (2 pcs.)
- Electrode Cleaning Solution Sachets (HI700601) (2 pcs.)
- pH and ORP Electrode Storage Solution 25 mL (HI70300S) (1 pc.)
- 3.5M KCl Electrolyte Solution 30 mL (HI7082) (1 pc.)
- Capillary Pipette (1 pc.)
- DO Smart Cap with O-ring (1 pc. of each)
- Calibration/Storage Vessel (1 pc. of each)
- Lens Cleaning Wipe (1 pc.)
- Syringe and Sachet with Silicon Grease (1 pc. of each)
- Electrode Holder (HI764060) (1pc) The following accessories include: base plate with integrated pivot pin and screw (requires installation), attached cable holder clip, attached electrode holder with adapter
- 24 VDC Power Adapter (1 pc.)
- USB-C to USB-A Cable (1 pc.)
- Meter Quick Reference Guide (1 pc.)
- Meter, Smart Cap, and Probes Quality Certificates
- Modules Hardware Quick Reference Guide and Quality Certificates
-
What's included with our
pH/ORP/ISE and DO Starter Kit- Multiparameter Modular System (HI6000-01)
- pH/ORP/ISE Module (HI6000-2) (1 pc.)
- DO Module (HI6000-4) (1 pc.)
- Refillable Combination pH Electrode with BNC Connector (HI1131B) (1 pc.)
- Temperature Probe (HI7662-TW) (1 pc.)
- Polarographic DO Probe (HI764833) (1 pc.)
- pH 4.01 Buffer Solution Sachets (2 pcs.)
- pH 7.01 Buffer Solution Sachets (4 pcs.)
- pH 10.01 Buffer Solution Sachets (2 pcs.)
- Electrode Cleaning Solution Sachets (HI700601) (2 pcs.)
- pH and ORP Electrode Storage Solution 25 mL (HI70300S) (1 pc.)
- 3.5M KCl Electrolyte Solution 30 mL (HI7082) (1 pc.)
- Polarographic DO Electrolyte Solution (30 mL) (HI7041S) (1 pc.)
- Capillary Pipette (1 pc.)
- DO Membrane Cap with O-ring (2 pcs.)
- Electrode Holder (HI764060) (1pc) The following accessories include: base plate with integrated pivot pin and screw (requires installation), attached cable holder clip, attached electrode holder with adapter
- 24 VDC Power Adapter (1 pc.)
- USB-C to USB-A Cable (1 pc.)
- Meter Quick Reference Guide (1 pc.)
- Meter and Probes Quality Certificates
- Modules Hardware Quick Reference Guide and Quality Certificates
-
Specifications
Specification Name Detail Sku HI6542 pH Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; - 2.000 to 20.000 pH pH Resolution 0.1 pH; 0.01 pH; 0.001 pH pH Accuracy ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) Calibration Points Up to 5 Calibration Type Automatic; Semiautomatic; Manual Standard Buffers Hanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) Custom Buffers Up to 5 Custom Group Option to select from eight standard buffers and user-defined custom buffers First Calibration Point Offset or Point (user setting) Isopotential Point -2.000 to 20.000 pH mV Range -2000.0 to 2000.0 mV mV Resolution 1 mV; 0.1 mV mV Accuracy ±0.2 mV ±1 last significant digit mV Calibration Single point offset, ±2000.0 mV ISE Range 1.0×10¯5 to 300.0 ppt (g/L or mg/mL)
5.0×10¯3 to 1.0×105 ppm (mg/L or µg/mL)
1.0 to 5.0×107 ppb (µg/L)
1.0×10¯7 to 10.0 M (mol/L)
1.0×10¯4 to 1.0×104 mmol/L
1.0×10¯6 to 60.0 %w/v
5.0×10¯7 to 5.0×107 userISE Resolution 1, 2, 3 significant digits ISE Accuracy ±0.5% (monovalent ions); ±1% (divalent ions) ISE Calibration Points Up to 5 ISE Calibration Type All Standards; Standard Group ISE Standards 7 standard solutions available for each concentration unit ISE Custom Standards Up to 5 ISE Custom Group Up to 5 Salinity Compensation Manual
> 0.00 to 45.00 PSU or ppt
> 0.0 to 130.0%DO Range 0.0 to 500.0 % saturation; 0.00 to 90.00 mg/L (ppm) concentration DO Resolution 0.1 % saturation; 0.01 mg/L (ppm) DO Accuracy Refer to probe used DO Calibration Points One or two points at 100.0 % (8.26 mg/L) and 0.0 % (0.00 mg/L) DO Calibration Type Automatic; Manual (user entered value in % saturation, mg/L, or ppm) Barometric Pressure Range 450.0 to 850.0 mmHg; 600.0 to 1133.2 mbar; 60.00 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm Barometric Pressure Resolution 0.1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm Barometric Pressure Accuracy ±3 mmHg within ±15 % from calibration point; ±3 mmHg ±1 least significant digit Barometric Pressure Compensation Automatic (meter-integrated barometer); Manual Temperature Range −20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K Temperature Resolution 0.1 °C; 0.1 °F; 0.1 K Temperature Accuracy For pH: ±0.2 °C; ±0.4 °F; ±0.2 K
For DO: Refer to probe usedTemperature Calibration Single point, adjustable Temperature Compensation Automatic; Manual Reading Mode Direct
Direct/Autohold
For ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction
For DO Only: OUR, SOUR, BODBasic View Measurement data; Measurement profile (if enabled); Stability status Simple GLP View Basic view information
For pH: Last calibration date, slope, offset (pH, Rel. mV - ISE only)
For DO: Last calibration date, offset, average slopeFull GLP View Simple GLP Information; Calibration point details (pH, ISE, and DO) Graph View Basic view information; Measurement versus time graph Table View Basic view information; Table with measurements updated every second Reading Stability Criteria Accurate; Medium; Fast Reading Sampling Rate 1000 ms Logging Type Automatic; Manual; Autohold Logging Number of Records 50,000 maximum per file and stores at least 1,000,000 data points per user Logging Automatic Interval 1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes Logging Sample ID Incremental Mode; Manual Logging Export Option .CSV file format Connectivity USB-A 2 ports
keyboard and/or printer input
USB Flash DriveConnectivity USB-C 1 port
PC Connectivity and USB-C Type Flash DriveConnectivity Wi-Fi & Ethernet FTP; Web Server (Log transfer and download); Email Connectivity RS232 Connecting peripherals Calibration Reminder Daily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled Users Up to 9 users and the default administrator account Power Supply DC adapter 100-240 VAC to 24 VDC 2A Environment 0 to 50 °C / 32 to 122 °F / 273 to 323 K maximum 95 % RH non-condensing Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 ") Weight 8.05 lbs -
Features
- This benchtop has a 7-inch touch screen color display (800 x 480p resolution)
- Up to 3 hardware modules can be installed on this benchtop. The installed hardware module is assigned to the measurement channel
- Up to 3 measurements can be displayed on the benchtop screen at one time and format options can be changed in settings
- Customize measurement and calibration options, create custom buffers, and more
- Equipped with a measurement stability indicator. This criteria can be adjusted in settings
- There are reading or module specific application modes (direct and direct/autohold)
- There's no need to update the sensor or benchtop system settings with application-specific probes for direct measurements
- Temperature compensation can be automatic when using a temperature probe or integral temperature sensor within probe. This can also be set manually
- Galvanic isolation for measurement modules
- Non-volatile memory saves data and settings
- Users can create alarms to be notified when parameters are out of desired ranges. Warnings will appear on the message banner and a beeping noise will sound if enabled
- Determine appropriate permission and password settings for each user, administrator or standard level, to prevent unwanted edits or changes to benchtop options and results
- Includes help menu for support with a brief overview of the main functionalities with descriptions and video tutorials
-
Connection Options
- Users can select the network to be connected via Ethernet, Wi-Fi, or disabled
- Conveniently transfer logged data as a .CSV file via email or FTP with Ethernet and Wi-Fi connection
- Export data via a USB Flash Drive or direct PC connection
- Download logs to a web client with the embedded web server
- Utilize a Thermal Printer (SP6000-PRN01) or keyboard with this benchtop via a USB-A port
- Up to 2 Mini Magnetic Stirrers (HI6000180) can be connected to this device via the two ports located on the back of the benchtop. Set the stirrer speed and the rotation direction
- This benchtop meter works with Hanna Instruments pH electrodes with a BNC connection
-
Reporting Capabilities
- Active data logging during measurement
- Includes three data-logging types: manual, automatic, and auto-hold
- Record up to 1 million data points with time and date stamp for easy reference. Sample ID is also documented which is ideal for manual and auto-hold data collection
- Method-specific application reports can be generated
- Product Manual
Easily modify your view options to suit your preferences
Up to 3 measurements can be shown on the benchtop screen at the same time. Various display configurations and formats are available and can be adjusted in settings.
Utilize a Mini Magnetic Stirrer to ensure sample consistency
HI6000180 $219.99
Streamline sample handling with a Mini Magnetic Stirrer. This piece of testing equipment automatically stirs for you, so that you can focus on other important tasks. Easily control the stirring speed and rotation direction by adjusting the slider on the benchtop screen or using the knob located on the front of the stirrer. Two stirrers can be connected to the benchtop at the same time.
Save time and maximize efficiency with a Thermal Printer
SP6000-PRN01 $679.99
Integrating a Thermal Printer as part of the quality assurance process is required in certain laboratories. Plus, it is a nice-to-have for added convenience. With its compact size, this printer takes up minimal space, making it an ideal choice for a lab setting. This printer simply connects to our pH/ORP/ISE and DO Benchtop Meter (HI6542). Quickly print and share data reports on the spot.
Customers also test with
Are you ready to grow? Expand to measure more with a custom Multiparameter Benchtop.Ask us how you can design your very own Benchtop Meter today! In addition to pH and DO, you can start measuring other parameters such as EC/TDS simultaneously. The measurement possibilities are endless with its plug-and-play design. With 3 bays in the back of the unit, you can mix and match any combination of modules.We'd like to hear more about your requirements and how we can create the best testing experience together.
|
|