HI6000-4
Dissolved Oxygen Module
$259.99Our Dissolved Oxygen module (HI6000-4) is compatible with our Multiparameter Modular System.
- The Dissolved Oxygen module (HI6000-4) enables accurate dissolved oxygen measurements in fresh and saltwater when paired with optical or polarographic probes
- Direct measurement, OUR, SOUR, and BOD methods with guided procedures for accurate results
Thank you for your interest in our products. A representative will contact you within the next business day.
Oxygen Measurement Methods
Direct measurement, OUR, SOUR, and BOD are supported with step-by-step guidance following standard methods. Concentration readings are automatically adjusted for barometric pressure, temperature, and salinity.
Log recall and sharing
Manage your own measurement data—view, delete, or share it. Data can be seen in tables (with date, time, and notes) or as graphs. Logs can be shared via USB, FTP, web server, or email.
Alarm configuration
Alarm configuration lets users set high and low limits. If measurements exceed these limits, an alarm triggers with a visual and optional sound alert.
Resources
-
Specifications
Specification Name Detail Sku HI6000-4 DO Range 0.0 to 500.0 % saturation; 0.00 to 90.00 mg/L (ppm) concentration DO Resolution 0.1 % saturation 0.01 mg/L (ppm) DO Accuracy Refer to probe used DO Calibration Points One or two points at 100.0 % (8.26 mg/L) and 0.0 % (0.00 mg/L) DO Calibration Type Automatic; Manual (user entered value in % saturation, mg/L, or ppm) Barometric Pressure Range 450.0 to 850.0 mmHg; 600.0 to 1133.2 mbar; 60.00 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm Barometric Pressure Resolution 0.1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm Barometric Pressure Accuracy ±3 mmHg within ±15 % from calibration point; ±3 mmHg ±1 least significant digit Barometric Pressure Compensation Automatic (meter-integrated barometer); Manual Temperature Range −20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K Temperature Resolution 0.1 °C; 0.1 °F; 0.1 K Temperature Accuracy Refer to probe used Temperature Calibration Single point, adjustable Reading Mode Direct; Direct/Autohold; OUR; SOUR; BOD Basic View Measurement data; Measurement profile (if enabled); Stability status Simple GLP View Basic view information; DO last calibration date, offset, average slope Full GLP View Simple GLP information; Calibration point details Graph View Basic view information; Measurement versus time graph Table View Basic view information; Table with measurements updated every second - Product Manuals