iris visible spectrophotometer with barcode reader
$3,499.00Our iris® visible spectrophotometer HI802 quickly identifies methods by scanning the barcode on reagent vials. It supports single-zero measurements and offers versatility with a removable barcode reader and cuvette adapters. Portable and capable of measuring all visible light wavelengths, this compact meter combines high performance with customize your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.
-
Automatic Method Identification: Saves time and reduces errors by automatically applying methods to vial samples.
-
103 Factory & 100 Custom Methods: Provides immediate options and flexibility with pre-set and customizable methods.
-
Vial Barcode Reader: Increases accuracy and efficiency with automatic vial scanning and identification.
Thank you for your interest in our products. A representative will contact you within the next business day.
Vial barcode reader
The HI802 automatically identifies barcoded sample vials, detecting method type and range to minimize errors and streamline measurements.
Vial rotation
Vial rotation during measurement enables method identification and multiple absorbance readings, which are converted to concentration units and displayed on the LCD. This rotational averaging improves method accuracy.
Shared single-zero measurement
Single-zero measurement with DI water blank correction ensures stable readings and reflects sample features, not instrument changes, for ease of use.
Spectral range
The meter features a spectral range of 340nm to 900nm allowing for a wide selection of analytical methods. The flexibility of this range permits compliance with many methods from regulatory organizations and associations for a variety of applications.
Advanced split–beam optical system.
In a spectrophotometer the optical system is the heart of the instrument. Ensuring that the optical system is built with the best design and highest quality materials will guarantee accurate readings and a long life for the meter. When developing this meter our research and development team payed special attention to details and combined many small improvements to a typical spectrophotometer design to create a portable meter with unprecedented performance.
The convenience of pre-programmed methods with the option to expand.
The HI802 comes with over 100 pre-programmed methods for chemical analysis. Methods can be updated via computer or flash drive, and up to 150 can be saved. It also provides reagent codes for easy ordering.
Easily access your favorite methods directly from the home screen to save time.
Program up to 100 custom methods with up to 10 calibration points, 5 simultaneous wavelengths, and 5 reaction timers. This flexibility allows for extensive customization beyond factory presets, accommodating specific needs and modifications.
Universal cuvette hold
The cuvette holder accommodates 22 mm round and 5 cm path length rectangular cuvettes, with adapters for 13 mm, 16 mm, and 10 mm cuvettes, including a 13 mm vial adapter with a barcode reader. It allows selection of cuvette size in custom methods and displays the size on screen for accurate measurements.
Worry free replacements.
iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.
Designed for dynamic environments.
The meter features a rechargeable lithium ion battery that lasts for approximately 3,000 measurements (excl. vial rotation). Lasting well over a day of use in the field there is no need to worry about the battery life while out working without a power supply. The meter can be quickly recharged with a dedicated fast charging adapter.
Quality data without the hassle.
Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.
Menu navigation that makes sense.
Quickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our “favorite methods” feature.
Sort and share your data.
Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that's best for you.
-
Parameters
Parameter Range Resolution Accuracy Wavelength Method Reagent Code Alkalinity 0 to 500 mg/L (as CaCO₃) 1 mg/L ±5 mg/L ±5% of reading at 25 °C 610 nm Bromocresol Green HI775-26 Reagents for 25 tests Alkalinity, Marine 0 to 300 mg/L (as CaCO₃) 1 mg/L ±5 mg/L ±5% of reading at 25 °C 610 nm Bromocresol Green HI755-26 Reagents for 25 tests Aluminum 0.00 to 1.00 mg/L (as Al³+) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 530 nm Adaptation of the Aluminon Method HI93712-01 Reagents for 100 tests; HI93712-03 Reagents for 300 tests Ammonia Low Range 0.00 to 3.00 mg/L (as NH₃-N) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 425 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method HI93700-01 Reagents for 100 tests; HI93700-03 Reagents for 300 tests Ammonia Low Range (13 mm Vial) 0.00 to 3.00 mg/L (as NH₃-N) 0.01 mg/L ±0.10 mg/L or ± 5% of reading at 25 °C, whichever is greater 425 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method HI93764A-25 Reagents for 25 tests Ammonia Low Range ISO (13 mm Vial) 0.000 to 2.500 mg/L (as NH₄+) 0.001 mg/L ±0.015 mg/L ± 3% of reading at 25 °C 690 nm ISO 23695 HI96791-25 Reagents for 25 tests Ammonia Medium Range 0.00 to 10.00 mg/L (as NH₃-N) 0.01 mg/L ±0.05 mg/L ± 5% of reading at 25 °C, whichever is greater 425 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method HI93715-01 Reagents for 100 tests; HI93715-03 Reagents for 300 tests Ammonia High Range 0.0 to 100.0 mg/L (as NH₄+) 0.1 mg/L ±0.5 mg/L ± 5% of reading at 25 °C 425 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler Method HI93733-01 Reagents for 100 tests; HI93733-03 Reagents for 300 tests Ammonia High Range (13 mm Vial) 0.0 to 100.0 mg/L (as NH₃-N) 0.1 mg/L ±1.0 mg/L or ± 5% of reading at 25 °C, whichever is greater 430 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler Method HI93764B-25 Reagents for 25 tests Bromine 0.00 to 10.00 mg/L (as Br₂) 0.01 mg/L ±0.08 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method HI93716-01 Reagents for 100 tests; HI93716-03 Reagents for 300 tests Calcium 0 to 400 mg/L (as Ca²+) 1 mg/L ±10 mg/L ±5% of reading at 25 °C 466 nm Adaptation of the Oxalate Method HI937521-01 Reagents for 50 tests; HI937521-03 Reagents for 150 tests Calcium, Marine 200 to 600 mg/L (as Ca²+) 1 mg/L ± 5% of reading at 25 °C 610 nm Adaptation of the Zincon Method HI758-26 Reagents for 25 tests Chloride 0.0 to 20.0 mg/L (as Cl-) 0.1 mg/L ±0.5 mg/L ±5% of reading at 25 °C 455 nm Adaptation of the Mercury (II) Thiocyanate Method HI93753-01 Reagents for 100 tests; HI93753-03 Reagents for 300 tests Chlorine Dioxide 0.00 to 2.00 mg/L (as ClO₂) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 575 nm Adaptation of the Chlorophenol Red Method HI93738-01 Reagents for 100 tests; HI93738-03 Reagents for 300 tests Chlorine Dioxide (Rapid) 0.00 to 2.00 mg/L (as ClO₂) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, 4500 ClO₂ D HI96779-01 Reagents for 100 tests; HI96779-03 Reagents for 300 tests Chlorine, Free Ultra Low Range 0.000 to 0.500 mg/L (as Cl₂) 0.001 mg/L ±0.020 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI95762-01 Reagents for 100 tests;HI95762-03 Reagents for 300 tests Chlorine, Free Low Range (Powder Reagent) 0.00 to 5.00 mg/L (as Cl₂) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-01 Reagents for 100 tests;HI93701-03 Reagents for 300 tests Chlorine, Free Low Range (Liquid Reagent) 0.00 to 5.00 mg/L (as Cl₂) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-F Reagents for 300 tests (liquid) Chlorine, Free High Range 0.00 to 10.00 mg/L (as Cl₂) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93734-01 Reagents for 100 tests; HI93734-03 Reagents for 300 tests Chlorine, Total Ultra Low Range 0.000 to 0.500 mg/L (as Cl₂) 0.001 mg/L ±0.020 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI95761-01 Reagents for 100 tests; HI95761-03 Reagents for 300 tests Chlorine, Total Low Range (Powder Reagent) 0.00 to 5.00 mg/L (as Cl₂) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93711-01 Reagents for 100 tests (powder); HI93711-03 Reagents for 300 tests (powder) Chlorine, Total Low Range (Liquid Reagent) 0.00 to 5.00 mg/L (as Cl₂) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-T Reagents for 300 tests (liquid) Chlorine, Total High Range 0.00 to 10.00 mg/L (as Cl₂) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93734-01 Reagents for 100 tests; HI93734-03 Reagents for 300 tests Chlorine, Total Ultra High Range 0 to 500 mg/L (as Cl₂) 1 mg/L ±3 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th Edition, 4500-Cl HI95771-01 Reagents for 100 tests; HI95771-03 Reagents for 300 tests Chromium (VI) Low Range 0 to 300 μg/L (as Cr(VI)) 1 μg/L ±10 μg/L ±4% of reading at 25 °C 535 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide Method HI93749-01 Reagents for 100 tests; HI93749-03 Reagents for 300 tests Chromium (VI) High Range 0 to 1000 μg/L (as Cr(VI)) 1 μg/L ±5 μg/L ±4% of reading at 25 °C 535 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide Method HI93723-01 Reagents for 100 tests; HI93723-03 Reagents for 300 tests Chromium (VI)/Total (13 mm Vial) 0 to 1000 μg/L (as Cr) 1 μg/L ±10 μg/L ± 3% of reading 525 nm Adaptation of the Standard Methods of the Examination of Water and Wastewater, 22nd Edition, 3500-Cr, Diphenylcarbazide Method HI96781-25 Reagents for 25 tests Chemical Oxygen Demand Low Range EPA (13 mm Vial) 0 to 150 mg/L (as O₂) 1 mg/L ±5 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754A-25 Reagents for 25 tests Chemical Oxygen Demand Low Range Mercury Free (13 mm Vial) 0 to 150 mg/L (as O₂) 1 mg/L ±5 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Dichromate Mercury Free HI93754D-25 Reagents for 25 tests Chemical Oxygen Demand Low Range ISO (13 mm Vial) 0 to 150 mg/L (as O₂) 1 mg/L ±5 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Dichromate ISO HI93754F-25 Reagents for 25 tests Chemical Oxygen Demand Medium Range EPA (13 mm Vial) 0 to 1500 mg/L (as O₂) 1 mg/L ±15 mg/L or ±3% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754B-25 Reagents for 25 tests Chemical Oxygen Demand Medium Range Mercury Free (13 mm Vial) 0 to 1500 mg/L (as O₂) 1 mg/L ±15 mg/L or ±3% of reading at 25 °C, whichever is greater 610 nm Dichromate Mercury Free HI93754E-25 Reagents for 25 tests Chemical Oxygen Demand Medium Range ISO (13 mm Vial) 0 to 1000 mg/L (as O₂) 1 mg/L ±15 mg/L or ±3% of reading at 25 °C, whichever is greater 610 nm Dichromate ISO HI93754G-25 Reagents for 25 tests Chemical Oxygen Demand High Range EPA (13 mm Vial) 0 to 15000 mg/L (as O₂) 1 mg/L ±150 mg/L or ±2% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewater HI93754C-25 Reagents for 25 tests Chemical Oxygen Demand Ultra High Range (13 mm Vial) 0.0 to 60.0 ppt (as O₂) 0.1 ppt ±0.5 ppt ±3% of reading @ 25°C 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754J-25 Reagents for 25 tests Color ADMI Low Range 0 to 250 ADMI Pt-Co 1 ADMI Pt-Co ±5 ADMI Pt-Co at 25 °C 400-700 nm ADMI weighted ordinate Method, analogous APHA 2120F Method — Color ADMI High Range 0 to 600 ADMI Pt-Co 1 ADMI Pt-Co ±20 ADMI Pt-Co at 25 °C 400-700 nm ADMI weighted ordinate Method, analogous APHA 2120F Method — Color of Water 0 to 500 PCU (Platinum Cobalt Units) 1 PCU ±10 PCU ±5% of reading at 25 °C 460 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Colorimetric Platinum Cobalt Method — Copper Low Range 0 to 1500 μg/L (as Cu) 1 μg/L ±10 μg/L ±5% of reading at 25 °C 575 nm Adaptation of the EPA Method HI95747-01 Reagents for 100 tests; HI95747-03 Reagents for 300 tests Copper High Range 0.00 to 5.00 mg/L (as Cu) 0.01 mg/L ±0.02 mg/L ±4% of reading at 25 °C 560 nm Adaptation of the EPA Method HI93702-01 Reagents for 100 tests; HI93702-03 Reagents for 300 tests Cyanide 0.000 to 0.200 mg/L (as CN-) 0.001 mg/L ±0.005 mg/L ±3% of reading at 25 °C 610 nm Pyridine-Pyrazalone HI93714-01 Reagents for 100 tests; HI93714-03 Reagents for 300 tests Cyanuric Acid 0 to100 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading at 25 °C 525 nm Adaptation of the Turbidimetric Method HI93722-01 Reagents for 100 tests; HI93722-03 Reagents for 300 tests Fluoride Low Range 0.00 to 2.00 mg/L (as F-) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method HI93729-01 Reagents for 100 tests; HI93729-03 Reagents for 300 tests Fluoride High Range 0.0 to 20.0 mg/L (as F-) 0.1 mg/L ±0.5 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method HI93739-01 Reagents for 100 tests; HI93739-03 Reagents for 300 tests Hardness, Calcium 0.00 to 2.70 mg/L (as CaCO₃) 0.01 mg/L ±0.08 mg/L ±4% of reading at 25 °C 523 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Calmagite Method HI93720-01 Reagents for 100 tests; HI93720-03 Reagents for 300 tests Hardness, Magnesium 0.00 to 2.00 mg/L (as CaCO₃) 0.01 mg/L ±0.11 mg/L ±5% of reading at 25 °C 523 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, EDTA Colorimetric Method HI93719-01 Reagents for 100 tests; HI93719-03 Reagents for 300 tests Hardness, Total Low Range 0 to 250 mg/L (as CaCO₃) 1 mg/L ±5 mg/L ±4% of reading at 25 °C 466 nm Adaptation of the EPA Method 130.1 HI93735-00 Reagents for 100 tests (LR); HI93735-0 Reagents for 300 tests (LR - 100 tests, MR - 100 tests, HR - 100 tests) Hardness, Total Medium Range 200 to 500 mg/L (as CaCO₃) 1 mg/L ±7 mg/L ±3% of reading at 25 °C 466 nm Adaptation of the EPA Method 130.1 HI93735-01 Reagents for 100 tests (MR); HI93735-0 Reagents for 300 tests (LR - 100 tests, MR - 100 tests, HR - 100 tests) Hardness, Total High Range 400 to 750 mg/L (as CaCO₃) 1 mg/L ±10 mg/L ±2% of reading at 25 °C 466 nm Adaptation of the EPA Method 130.1 HI93735-02 Reagents for 100 tests (HR); HI93735-0 Reagents for 300 tests (LR - 100 tests, MR - 100 tests, HR - 100 tests) Hydrazine 0 to 400 μg/L (as N₂H₄) 1 μg/L ±3 μg/L ±3 % of reading at 25°C 466 nm Adaptation of the ASTM Manual of Water and Environmental Technology, Method D1385,p- Dimethylaminobenzaldehyde Method HI93704-01 Reagents for 100 tests; HI93704-03 Reagents for 300 tests Iodine 0.0 to 12.5 mg/L (as I₂) 0.1 mg/L ±0.1 mg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method HI93718-01 Reagents for 100 tests; HI93718-03 Reagents for 300 tests Iron Low Range 0.000 to 1.600 mg/L (as Fe) 0.001 mg/L ±0.010 mg/L ±8% of reading at 25 °C 575 nm Adaptation of the TPTZ Method HI93746-01 Reagents for 50 tests; HI93746-03 Reagents for 150 tests Iron High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI93721-01 Reagents for 100 tests; HI93721-03 Reagents for 300 tests Iron (II) (Ferrous) 0.00 to 6.00 mg/L (as Fe²+) 0.01 mg/L ±0.10 mg/L ±2% of reading at 25 °C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96776-01 Reagents for 100 tests; HI96776-03 Reagents for 300 tests Iron (13 mm Vial) 0.00 to 6.00 mg/L (as Fe) 0.01 mg/L ±0.10 mg/L or ±3% of reading at 25°C 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96786-25 Reagents for 25 tests Iron Total (13 mm Vial) 0.00 to 7.00 mg/L (as Fe) 0.01 mg/L ±0.20 mg/L or± 3% of reading, whichever is greater 525 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method HI96778-25 Reagents for 25 tests Magnesium 0 to 150 mg/L (as Mg²+) 1 mg/L ±5 mg/L ±3% of reading at 25 °C 466 nm Adaptation of the Calmagite Method HI937520-01 Reagents for 50 tests; HI937520-03 Reagents for 150 tests Magnesium, Marine 1000 to 1800 mg/L (as Mg²+) 5 mg/L ±5% of reading 640 nm Adaptation of Colorimetric EDTA Method using calmagite indicator HI783-25 Reagents for 25 tests Manganese Low Range 0 to 300 μg/L (as Mn) 1 μg/L ±7 μg/L ±3% of reading at 25 °C 560 nm Adaptation of the PAN Method HI93748-01 Reagents for 50 tests; HI93748-03 Reagents for 150 tests Manganese High Range 0.0 to 20.0 mg/L (as Mn) 0.1 mg/L ±0.2 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Periodate Method HI93709-01 Reagents for 100 tests; HI93709-03 Reagents for 300 tests Maple Syrup 0.00 to 100.00 %T 0.01 %T ±3% of reading at 25 °C 560 nm Direct Measure HI93703-57 Glycerol (4 pcs.), 30 mL Molybdenum 0.0 to 40.0 mg/L (as Mo⁶+) 0.1 mg/L ±0.3 mg/L ±5% of reading at 25 °C 420 nm Adaptation of the Mercaptoacetic Acid Method HI93730-01 Reagents for 100 tests; HI93730-03 Reagents for 300 tests Nickel Low Range 0.000 to 1.000 mg/L (as Ni) 0.001 mg/L ±0.010 mg/L ±7% of reading at 25 °C 565 nm Adaptation of the PAN Method HI93740-01 Reagents for 50 tests; HI93740-03 Reagents for 150 tests Nickel High Range 0.00 to 7.00 ppt (as Ni) 0.01 ppt ±0.07 ppt±4% of reading at 25 °C 575 nm Adaptation of the Photometric Method HI93726-01 Reagents for 100 tests; HI93726-03 Reagents for 300 tests Nitrate 0.0 to 30.0 mg/L (as NO₃¯-N) 0.1 mg/L ±0.5 mg/L ±10% of reading at 25 °C 525 nm Adaptation of the Cadmium Reduction Method HI93728-01 Reagents for 100 tests; HI93728-03 Reagents for 300 tests Nitrate Chromotropic Acid (13 mm Vial) 0.0 to 30.0 mg/L (as N0₃¯-N) 0.1 mg/L ±1.0 mg/L or ±3% of reading at 25 °C, whichever is greater 410 nm Chromotropic Acid Method HI93766-50 Reagents for 50 tests Nitrate, Marine High Range 0.0 to 75.0 mg/L (as N0₃¯) 0.1 mg/L ±2.0 mg/L ± 5 % of reading 505 nm Zinc Reduction Method HI782-25 Reagents for 25 tests Nitrite Low Range 0 to 600 μg/L (as NO₂¯-N) 1 μg/L ±20 μg/L ±4% of reading at 25 °C 480 nm Adaptation of the EPA Diazotization Method 354.1 HI93707-01 Reagents for 100 tests; HI93707-03 Reagents for 300 tests Nitrite Low Range (13 mm Vial) 0 to 600 μg/L (as NO₂¯-N) 1 μg/L ±10 μg/L ± 3% of reading at 25°C, whichever is greater 525 nm Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 4500B Diazotization Method, Nitrogen Nitrite HI96783-25 Reagents for 25 tests Nitrite Medium Range (13 mm Vial) 0.00 to 6.00 mg/L (as NO₂¯-N) 0.01 mg/L ±0.10 mg/L ± 3% of reading at 25°C 525 nm Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 4500B Diazotization Method, Nitrogen Nitrite HI96784-25 Reagents for 25 tests Nitrite High Range 0 to 150 mg/L (as NO₂¯) 1 mg/L ±4 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the Ferrous Sulfate Method HI93708-01 Reagents for 100 tests; HI93708-03 Reagents for 300 tests Nitrite, Marine Ultra Low Range 0 to 200 μg/L (as N0₂¯-N) 1 μg/L ±8 μg/L ±4% of reading at 25 °C 480 nm Adaptation of the EPA Diazotization Method 354.1 HI764-25 Reagents for 25 tests Nitrite, Seawater (13 mm Vial) 0 to 600 μg/L (as N0₂¯-N) 1 μg/L ±15 μg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 4500B Diazotization Method, Nitrogen Nitrite HI96789-25 Reagents for 25 tests Nitrogen, Total Low Range (13 mm Vial) 0.0 to 25.0 mg/L (as N) 0.1 mg/L ±1.0 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm Chromotropic Acid Method HI93767A-50 Reagents for up to 50 tests Nitrogen, Total High Range (13 mm Vial) 10 to 150 mg/L (as N) 1 mg/L ±3 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Chromotropic Acid Method HI93767B-50 Reagents for up to 50 tests Oxygen, Dissolved 0.0 to 10.0 mg/L (as O₂) 0.1 mg/L ±0.4 mg/L ±3% of reading at 25 °C 466 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Azide Modified Winkler Method HI93732-01 Reagents for 100 tests; HI93732-03 Reagents for 300 tests Oxygen Scavengers (Carbohydrazide) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.01 mg/L ±0.02 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests; HI96773-03 Reagents for 150 tests Oxygen Scavengers (Diethylhydroxylamine) (DEHA) 0 to 1000 μg/L (as DEHA) 1 μg/L ±5 μg/L ±5% of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests; HI96773-03 Reagents for 150 tests Oxygen Scavengers (Hydroquinone) 0.00 to 2.50 mg/L (as Hydroquinone) 0.01 mg/L ±0.04 mg/L ±3% of reading at 25 °C 575 nm Adaptation of Iron Reduction Method HI96773-01 Reagents for 50 tests; HI96773-03 Reagents for 150 tests Oxygen Scavengers (Isoascorbic Acid) 0.00 to 4.50 mg/L (as Iso-Ascorbic Acid) 0.01 mg/L ±0.03 mg/L ±3 % of reading at 25 °C 575 nm Adaptation of the Iron Reduction Method HI96773-01 Reagents for 50 tests; HI96773-03 Reagents for 150 tests Ozone 0.00 to 2.00 mg/L (as O₃) 0.01 mg/L ±0.02 mg/L ±3% of reading at 25 °C 525 nm Colorimetric DPD Method HI93757-01 Reagents for 100 tests; HI93757-03 Reagents for 300 tests; HI93703-52 Reagents for 100 tests (Optional) pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH at 25 °C 525 nm Adaptation of the Phenol Red Method HI93710-01 Reagents for 100 pH tests; HI93710-03 Reagents for 300 pH tests Phenols (13 mm Vial) 0.00 to 5.00 mg/L 0.01 mg/L ±0.05 mg/L ±3 % of reading at 25 °C 510 nm Adaptation of 4‑aminoantipyrine Method EPA 420.1 HI96788-25 Reagents for 25 tests Phosphate Low Range 0.00 to 2.50 mg/L (as PO₄³¯) 0.01 mg/L ±0.04 mg/L ±4% of reading at 25 °C 610 nm Adaptation of the Ascorbic Acid Method HI93713-01 Reagents for 100 tests; HI93713-03 Reagents for 300 tests Phosphate High Range 0.0 to 30.0 mg/L (as PO₄³¯) 0.1 mg/L ±1.0 mg/L ±4% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Amino Acid Method HI93717-01 Reagents for 100 tests; HI93717-03 Reagents for 300 tests Phosphorus, Acid Hydrolyzable (13 mm Vial) 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±5% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI93758B-50 Reagents for 50 tests Phosphorus, Reactive Low Range (13 mm Vial) 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±4% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI93758A-50 Reagents for 50 tests Phosphorus, Reactive High Range (13 mm Vial) 0.0 to 32.6 mg/L (as P) 0.1 mg/L ±0.5 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P C, Vanadomolybdophosphoric Acid Method HI93763A-50 Reagents for up to 50 tests Phosphorus, Total Low Range (13 mm Vial) 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±5% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P E, Ascorbic Acid Method HI93758C-50 Reagents for 50 tests Phosphorus, Total High Range (13 mm Vial) 0.0 to 32.6 mg/L (as P) 0.1 mg/L ±0.5 mg/L or ±5% of reading at 25 °C, whichever is greater 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th Edition, 4500-P C, Vanadomolybdophosphoric Acid Method HI93763B-50 Reagents for up to 50 tests Phosphorus, Marine Ultra Low Range 0 to 200 μg/L (as P) 1 μg/L ±5 μg/L ±5% of reading at 25 °C 610 nm Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method HI736-25 Reagents for 25 tests Potassium Low Range 0.0 to 20.0 mg/L (as K) 0.1 mg/L ±2 mg/L ±7% of reading at 25 °C 466 nm Adaptation of the Turbidimetric Tetraphenylborate Method HI93750-01 Reagents for 100 tests; HI93750-03 Reagents for 300 tests Potassium Medium Range 10 to 100 mg/L (as K) 1 mg/L ±10 mg/L ±7% of reading at 25 °C 466 nm Adaptation of the Turbidimetric Tetraphenylborate Method HI93750-01 Reagents for 100 tests; HI93750-03 Reagents for 300 tests Potassium High Range 20 to 200 mg/L (as K) 1 mg/L ±20 mg/L ±7% of reading at 25 °C 466 nm Adaptation of the Turbidimetric Tetraphenylborate Method HI93750-01 Reagents for 100 tests; HI93750-03 Reagents for 300 tests Silica Low Range 0.00 to 2.00 mg/L (as SiO₂) 0.01 mg/L ±0.03 mg/L ±5% of reading at 25 °C 610 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue Method HI93705-01 Reagents for 100 tests; HI93705-03 Reagents for 300 tests Silica High Range 0 to 200 mg/L (as SiO₂) 1 mg/L ±1 mg/L ±5% of reading at 25 °C 466 nm Adaptation of the EPA Method 370.1 for Drinking, Surface and Saline Waters, Domestic and Industrial Wastes and Standard Method 4500-SiO₂ HI96770-01 Reagents for 100 tests; HI96770-03 Reagents for 300 tests Silver 0.000 to 1.000 mg/L (as Ag) 0.001 mg/L ±0.020 mg/L ±5% of reading at 25 °C 570 nm Adaptation of the PAN Method HI93737-01 Reagents for 50 tests; HI93737-03 Reagents for 150 tests Sulfate 0 to 150 mg/L (as SO₄²¯) 1 mg/L ±5 mg/L ±3% of reading at 25 °C 466 nm Sulfate is precipitated with barium chloride crystals HI93751-01 Reagents for 100 tests; HI93751-03 Reagents for 300 tests Surfactants, Anionic 0.00 to 3.50 mg/L (as SDBS) 0.01 mg/L ±0.04 mg/L ±3% of reading at 25 °C 610 nm Adaptation of the EPA Method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th Edition, 5540C, Anionic Surfactants as MBAS HI95769-01 Reagents for 40 tests Surfactants, Anionic (13 mm Vial) 0.00 to 3.50 mg/L (as SDBS) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 610 nm Adaptation of the Standard Method for the Examination of Water and Wastewater, 23rd Edition, 5540C, Anionic Surfactants as MBAS HI96782-25 Reagents for 25 tests Surfactants, Cationic (13 mm Vial) 0.00 to 2.50 mg/L (as CTAB) 0.01 mg/L ±0.15 ppm ±3% of reading at 25°C 420 nm Bromophenol Blue Method HI96785-25 Reagents for 25 tests Surfactants, Nonionic (13 mm Vial) 0.00 to 6.00 mg/L (TRITON X-100) 0.01 mg/L ±0.10 mg/L ±5% of reading at 25 °C 610 nm TBPE Method HI96780-25 Reagents for 25 tests Zinc 0.00 to 3.00 mg/L (as Zn) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 620 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Zincon Method HI93731-01 Reagents for 100 tests; HI93731-03 Reagents for 300 tests
Resources
-
Specifications
Specification Name Detail sku HI802 Wavelength Range 340 to 900 nm Wavelength Resolution 1 nm Wavelength Accuracy ±1.5 nm Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, ºf, ºe, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, ºdH, meq/kg or no measurement unit) Wavelength Selection automatic, based on the selected method (editable for user methods only) Light Source tungsten halogen lamp Optical System split beam sample and reference light detectors Wavelength Calibration internal, automatic at power-on, visual feedback Stray Light <0.1 % T at 340 nm with NaNO2 Spectral bandwidth 5 nm (full width at half maximum) Sample Cell 16 mm round, 22 mm round, 13 mm vial, 10 mm square, 50 mm rectangular (with automatic detection) Programs (Factory/User) up to 150 factory (85 pre-loaded); up to 100 user developed Data points stored 9999 measured values Export Capability .csv file format, .pdf file format Connectivity (1) USB - A (mass storage host); (1) USB - B (mass storage device) Battery Type / Life 3000 measurements or 8 hours Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH Dimensions 155 x 205 x 322 mm (6.1 x 8.0 x 12.6") Weight 3 kg (6.6 lbs) Ordering Information HI802-01 (115V) and HI802-02 (230V) is supplied with sample cuvette and cap, 22 mm (4 pcs.), cuvette adapter (3 pcs.), vial adapter with barcode reading feature , cloth for wiping cuvettes, scissors, USB cable, 15 VDC power adapter, USB flash drive, instrument quality certificate, and instruction manual. Warranty 2 years Note *excluding vial rotation - Manual