Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter
$1,399.99HI83314 is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 10 key water and wastewater quality parameters with 20 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83314 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. To save valuable laboratory benchtop space, the HI83314 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.
- Advanced optical system
- Unparalleled performance from a benchtop photometer
- Digital pH electrode input
- Save valuable bench space with one meter that works both as a photometer and as a laboratory pH meter
- Wastewater Treatment Digestion Parameters
- Measures common wastewater parameters including COD, Total Nitrogen and Total Phosphorus
Thank you for your interest in our products. A representative will contact you within the next business day.
HI83314 benchtop photometer measures 10 different key wastewater quality parameters using 20 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process. This photometer features an innovative optical system that uses LED's, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.
A digital pH electrode input is provided allowing the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.
Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.
The HI83314 offers an absorbance measuring mode that allows for CAL CheckTM standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the 4 wavelengths of light (420 nm, 466 nm, 525 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for education to teach the concept of absorbance by using the Beer-Lambert Law.
Please note, reagents are not included and can be purchased here.
Features and Benefits
Digital pH Electrode Input
- Measure pH and temperature with a single probe
- Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability
- pH CAL CheckTM alerts user to potential problems during the calibration process
- Space saving having a pH meter and photometer built into one meter
Data Logging
- Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button.
- Sample ID and User ID information can be added to a logged reading using alphanumeric keypad
Connectivity
- Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port
- Data is exported as a .CSV file for use with common spreadsheet programs
Battery Status Indicator
- Indicates the amount of battery life left
Error Messages
- Photometric error messages include no cap, high zero, and standard too low
- pH calibration messages include clean electrode, check buffer and check probe
Backlit 128 x 64 Pixel Graphic LCD Display
- Backlit graphic display allows for easy viewing in low light conditions
- The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter
Built-in Reaction Timer for Photometric Measurements
- The measurement is taken after the countdown timer expires.
- Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements
Absorbance mode
- Hanna's exclusive CAL CheckTM cuvettes for validation of light source and detector
- Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry
Units of Measure
- Appropriate unit of measure along with chemical form is displayed along with reading
Result Conversion
- Automatically convert readings to other chemical forms with the touch of a button
Cuvette Cover
- Aids in preventing stray light from affecting measurements
On-Screen Features
Digestion Parameters Features
Advanced Optical System
-
Parameters
Parameter Range Resolution Accuracy (at 25 °C) Method Wavelength Reagent Code Absorbance 0.000 to 4.000 Abs 0.001 Abs +/-0.003Abs @ 1.000 Abs Ammonia, Low Range 0.00 to 3.00 mg/L (as NH3 -N) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method. 420 nm HI93700-01 Ammonia, Medium Range 0.00 to10.00 mg/L (as NH3-N) 0.01 mg/L ±0.05 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93715-01 Ammonia, High Range 0.0 to 100.0 mg/L (as NH3 -N) 0.1 mg/L ±0.5 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93733-01 Chemical Oxygen Demand, Low Range 0 to 150 mg/L (as O2 ) 1 mg/L ±5 mg/L or ±4% of reading Adaptation of the USEPA 410.4 420 nm HI93754A-25 Chemical Oxygen Demand, Medium Range 0 to 1500 mg/L (as O2 ) 1 mg/L ±15 mg/L or ±4% of reading Adaptation of the USEPA 410.4 610 nm HI93754B-25 Chemical Oxygen Demand, High Range 0 to 15000 mg/L (as O2 ) 1 mg/L ±150 mg/L or ±2% of reading Adaptation of the USEPA 410.4 610 nm HI93754C-25 Chlorine, Free 0.00 to 5.00 mg/L (as Cl2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93701-01 Chlorine, Total 0.00 to 5.00 mg/L (as Cl2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93711-01 Iron, Total (16 mm Vial) 0.00 to 7.00 mg/L (as Fe) 0.01 mg/L ±0.20 mg/L ±3% of reading Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method 525 nm HI96778-50 Nitrate 0.0 to 30.0 mg/L (as NO3 - N) 0.1 mg/L ±0.5 mg/L ±10% of reading Adaptation of the cadmium reduction method 525 nm HI93728-01 Nitrite, Low Range 0 to 600 µg/L (as NO2 -N) 1 µg/L ±20 µg/L ±4% of reading Adaptation of the EPA Diazotization method 354.1 466 nm HI93707-01 Nitrite, High Range 0 to 150 mg/L (as NO2-) 1 mg/L ±4 mg/L ±4% of reading Adaptation of the Ferrous Sulfate method 575 nm HI93708-01 Nitrogen, Total Low Range 0.0 to 25.0 mg/L (as N) 0.1 mg/L ±1.0 mg/L or ±5% of reading Chromotropic acid method 420 nm HI93767A-50 Nitrogen, Total High Range 0 to 150 mg/L (as N) 1 mg/L ±3 mg/L or ±4% of reading Chromotropic acid method 420 nm HI93767B-50 pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH Adaptation of the Phenol Red method 525 nm HI93710-01 Phosphorous, Reactive Low Range 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±4% of reading Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. 610 nm HI93758A-50 Phosphorous, Reactive High Range 0.0 to 32.6 mg/L (as P) 0.1 mg/L ±0.5 mg/L or ±4% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method. 420 nm HI93763A-50 Phosphorous, Acid Hydrolyzable 0.00 to 1.60 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±5% of reading Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. 610 nm HI93758B-50 Phosphorous, Total Low Range 0.00 to 1.15 mg/L (as P) 0.01 mg/L ±0.05 mg/L or ±6% of reading Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. 610 nm HI93758C-50 Phosphorous, Total High Range 0.0 to 32.6 mg/L (as P) 0.1 mg/L ±0.5 mg/L or ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method. 420 nm HI93763B-50
Resources
-
Specifications
Specification Name Detail sku HI83314-01 Wavelength Accuracy ±1 nm Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters Spectral bandwidth 8 nm Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode digital pH electrode (not included) Logging Type log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity GLP calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Battery Type / Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Environment 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8") Weight 1.0 kg (2.2 lbs.) Photometer/Colorimeter Light Detector silicon photodetector Cuvette Type round, 24.6 mm Number of Methods 128 max. Ordering Information Supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. Warranty 2 years Note *Reagents are not included. - Product Manuals