HI6000-3
EC/TDS Module
$259.99Our EC/TDS module (HI6000-3) is compatible with our Multiparameter Modular System.
- Your choice of measurement Unit: Conductivity – μS/cm, mS/cm, Resistivity – Ω•cm, kΩ•cm, MΩ•cm, TDS – ppm, ppt, and Salinity – (ppt, PSU, %)
- Automated Guidance and Verification that provides step-by-step instructions and automatically ensures USP limits for temperature, conductivity, and stability, ensuring accurate results
Thank you for your interest in our products. A representative will contact you within the next business day.
USP start screen
The screen displays stability, logging, and reading, with quick access to switch to USP mode.
USP meter verification screen
The USP meter verification screen is an interface on a testing instrument used to confirm its accuracy according to United States Pharmacopeia (USP) standards.
Log recall, sharing, and reports
Manage your own measurement data—view, delete, or share it. Data can be seen in tables (with date, time, and notes) or as graphs. Logs can be shared via USB, FTP, web server, or email. Reports of each analysis are recorded for download.
Resources
-
Specifications
Specification Name Detail Sku HI6000-3 Conductivity Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm Conductivity Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm Conductivity Accuracy ±1 % of reading or ±0.010 μS/cm, whichever is greater Conductivity Cell Constant 0.0500 to 200.0000 /cm Conductivity Calibration Type Automatic; Manual Conductivity Calibration Points Single Up to 5 Conductivity Calibration Solutions 84 μS/cm; 1413 μS/cm; 5000 μS/cm; 12880 μS/cm; 80000 μS/cm; 111800 μS/cm Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm Resistivity Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm Resistivity Accuracy ±1 % of reading or ±1 Ω•cm, whichever is greater Total Dissolved Solids (TDS) Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) Total Dissolved Solids (TDS) Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt Total Dissolved Solids (TDS) Accuracy ±1 % of reading or ±0.01 ppm, whichever is greater Salinity Range 0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale) Salinity Resolution 0.01 PSU; 0.01 ppt; 0.1 % Salinity Accuracy ±1 % of reading Salinity Calibration 1 point, using 100 % salinity calibration solution (% scale only) Temperature Range -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.2 to 393.2 K Temperature Resolution 0.1 °C; 0.1 °F; 0.1K Temperature Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K Temperature Calibration Single point, adjustable Reference Temperature 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K) Temperature Coefficient 0.00 to 10.00 %/°C Reading Mode Direct; Direct/Autohold; Direct/USP (Conductivity only) Basic View Measurement data; Measurement profile (if enabled); Stability status Simple GLP View Basic view information; Last calibration date and offset Full GLP View Simple GLP information; Calibration point details (conductivity and salinity) Graph View Basic view information; Measurement versus time graph Table View Basic view information; table with measurements updated every second - Product Manuals