Glass Body Calomel Reference Electrode for Measurements with Remote Filling
$174.99The HI5412 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a double ceramic junction in the outer reference cell, calomel references, and side arm construction. This design consideration is made for use in applications that require remote filling in temperatures ranging from -5 to 60°C.
- Refillable Electrode
- Calomel References
- Side Arm Construction
Thank you for your interest in our products. A representative will contact you within the next business day.
Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.
The HI5412 uses a glass body, single ceramic junction, calomel references and is refillable with 3.5M KCl.
Glass Body
The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature-dependent. The faster the equilibrium the steadier the reference potential.
Single Ceramic Junction
The outer junction of an electrode, also known as a salt bridge, is a necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 µL/hour. Other junction types are available with higher flow rates and made with different materials.
Refillable
The HI5412 is a refillable reference electrode. Since it is a double junction electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with a single-junction electrode. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings.
4 mm Connector
The HI5412 uses a 4 mm banana connector. This type of connector is easily plugged into the reference input on suitable meters. Other types of connectors include BNC, DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.
Resources
-
Specifications
Specification Name Detail SKU HI5412 Description reference electrode Reference single, Hg/Hg2Cl2 Junction / Flow Rate ceramic, single / 15-20 µL/h Electrolyte KCl 3.5M Max Pressure 0.1 bar Recommended Operating Temperature -5 to 60°C (23 to 140°F) Body Material glass Cable 1 m (3.3’) Recommended Use general purpose, titrations Connection 4 mm banana