HI98191
Professional Waterproof Portable pH/ORP/ISE Meter
$799.99The HI98191 is a rugged, portable pH/ORP/ISE meter with the performance and features of a benchtop meter. This professional, waterproof meter complies with IP67 standards and measures pH, ORP, ISE, and temperature. The HI98191 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable carrying case.
- CAL Check™
- ISE in Choice of Concentration Units
- Ergonomic, One-Handed Operation
For ORP measurements, use either the HI3131B or HI3230B electrodes.
Thank you for your interest in our products. A representative will contact you within the next business day.
For the measurement of pH the HI98191 comes with a HI72911B titanium body pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium body is chemically resistant to aggressive chemicals and is virtually unbreakable.
Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.
The HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, μg/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010.
Pressing the "AutoHold" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
The log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.
Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.
The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.
Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.
The HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, μg/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010.
Pressing the "AutoHold" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
The log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.
Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.
The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.
On-Screen Features
Setup Screen
Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.
Calibration
pH calibration features detailed CAL Check™ messages. Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.
GLP
Comprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.
ISE Measurements
The HI98191 includes ISE measurements when used with our wide selection of ISE electrodes or a custom version.
Features and Benefits
Ergonomic, rugged, waterproof (IP67) design
pH CAL Check™
- Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.
- Displays overall probe condition based on offset and slope after calibration
ISE direct concentration readout in a choice of concentration units
Automatic Temperature Compensation
Five-point pH calibration with seven standard buffers and five custom buffers
Log-on-demand
- Store measurement data at the press of a button
AutoHold
- Freezes a stable reading on the display for recording or logging
GLP features
- GLP data including date, time, calibrated values, slope and offset (pH)
Calibration timeout to alert the user at a defined interval when the calibration has expired
Multiple language selection
200-hour battery life with battery level displayed on measurement screen
Menu driven for ease of use with virtual-key extended functionality
Contextual help at the press of a button
Backlit, graphic LCD
Connectivity
- PC connectivity via a sealed opto-isolated micro USB and HI92000 software
PRIMARY APPLICATIONS: Food & Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental.
Resources
-
Specifications
Specification Name Detail sku HI98191 pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH pH Resolution 0.1 pH / 0.01 pH / 0.001 pH pH Accuracy @ 25°C / 77°F ±0.1 pH / ±0.01 pH / ±0.002 pH pH Calibration Up to five point calibration, seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and five custom buffers mV Range ±2000.0 mV mV Resolution 0.1 mV mV Accuracy ±0.2 mV Temperature Range -20.0 to 120.0 °C (-4.0 to 248.0 °F) Temperature Resolution 0.1 °C (0.1 °F) Temperature Accuracy @ 25°C / 77°F ±0.4 °C (±0.8 °F) (excluding probe error) ISE Range from 1.00 E⁻⁷ to 9.99 E¹⁰ concentration ISE Resolution 3 digits 0.01; 0.1; 1; 10 concentration ISE Accuracy ±0.5% of reading (monovalent ions), ±1% of reading (divalent ions) ISE Calibration up to five point calibration, six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm) Temperature Compensation manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) Log Feature On demand, 200 samples (100 pH and 100 mV) Connectivity PC Connectivity - opto-isolated USB with optional HI 92000 software and micro USB cable GLP Yes Power Supply 1.5V AA batteries (4 pcs.) Power Consumption approx. 200 hours of continuous use without backlight (50 hours with backlight) Environment 6 to 50 °C (32 to 122 °F) max. RH 100% IP67 Dimensions 191 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) Weight 406 g (14.2 oz) Ordering Information HI98191 is supplied with HI72911B titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720191 hard carrying case. Warranty 2 years Recommended Probe HI72911B Titanium body, pH electrode with internal temperature sensor, BNC connector and 1 m (3.3’ cable) - Product Manuals