The HI98191 is a rugged, portable pH/ORP/ISE meter with the performance and features of a benchtop meter. This professional, waterproof meter complies with IP67 standards and measures pH, ORP, ISE, and temperature. The HI98191 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable carrying case.
For ORP measurements, use either the HI3131B or HI3230B electrodes.
PRIMARY APPLICATIONS: Food & Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental.
Specification | Detail |
---|---|
sku | HI98191 |
pH Range | -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH |
pH Resolution | 0.1 pH / 0.01 pH / 0.001 pH |
pH Accuracy @ 25°C / 77°F | ±0.1 pH / ±0.01 pH / ±0.002 pH |
pH Calibration | Up to five point calibration, seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and five custom buffers |
mV Range | ±2000.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.2 mV |
Temperature Range | -20.0 to 120.0 °C (-4.0 to 248.0 °F) |
Temperature Resolution | 0.1 °C (0.1 °F) |
Temperature Accuracy @ 25°C / 77°F | ±0.4 °C (±0.8 °F) (excluding probe error) |
ISE Range | from 1.00 E⁻⁷ to 9.99 E¹⁰ concentration |
ISE Resolution | 3 digits 0.01 0.1 1 10 concentration |
ISE Accuracy | ±0.5% of reading (monovalent ions), ±1% of reading (divalent ions) |
ISE Calibration | up to five point calibration, six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm) |
Temperature Compensation | manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) |
Log Feature | On demand, 200 samples (100 pH and 100 mV) |
Connectivity | PC Connectivity - opto-isolated USB with optional HI 92000 software and micro USB cable |
GLP | Yes |
Power Supply | 1.5V AA batteries (4 pcs.) |
Power Consumption | approx. 200 hours of continuous use without backlight (50 hours with backlight) |
Environment | 6 to 50 °C (32 to 122 °F) max. RH 100% IP67 |
Dimensions | 191 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in.) |
Weight | 406 g (14.2 oz) |
Ordering Information | HI98191 is supplied with HI72911B titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720191 hard carrying case. |
Warranty | 2 years |
Recommended Probe | HI72911B Titanium body, pH electrode with internal temperature sensor, BNC connector and 1 m (3.3' cable) |