pH, Alkalinity, Free Chlorine, Total Chlorine, and Cyanuric Acid Photometer
$349.99The HI97104 pH, Alkalinity, Free Chlorine, Total Chlorine, and Cyanuric Acid Photometer combines accuracy and ease of use in a simple, portable design. The advanced optical system provides lab-quality accuracy while its user-friendly design is easy for any user making it the perfect photometer for your water quality testing needs. The HI97710 meter measures five important parameters commonly used in the treatment and disinfection of drinking water, waste water, and swimming pools.
- No warm up time needed before taking a measurement.
- Tutorial mode for easy step-by-step instructions.
- CAL CheckTM for performance verification and calibration.
*Products classified as Dangerous Goods can only be shipped via ground.
Thank you for your interest in our products. A representative will contact you within the next business day.
Better Features for Better Testing
Let your photometer guide you through setup, calibration, and testing with on-screen tutorials and animations so you always know the next step. Simply access Tutorial Mode at any stage in the setup or measurement process with the dedicated help key.
The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.
When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.
Data Logging
Missed a measurement? No need to worry because your photometer will automatically log the last 50 measurements. The results can be viewed instantly using the Log Recall Menu.
CAL Check™ Validation
Hanna’s exclusive CAL Check™ feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL Check™ standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.
Advanced Optical System
A Light Emitting Diode (LED) provides more light while using less power and a narrow band interference filter results in more accurate and repeatable readings.
Built Better
Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. Internal optics are sealed from outside dust, dirt, and water. In addition, it floats, just in case you drop your meter in water. This photometer uses an exclusive positive‑locking system to ensure that the cuvettes are placed into the holder in the same position for accurate readings every time.
Portable Design
Made to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle, day or night. The supplied AA batteries provide life for more than 800 measurements.
- Sample cuvette (2 pcs.)
- Sample cap (2 pcs.)
- Plastic stopper (2 pcs.)
- Alkaline batteries: 1.5V AA (3 pcs.)
- Instruction manual
- Meter quality certificate
Upgrade to the pH, Alkalinity, Free Chlorine, Total Chlorine and Cyanuric Acid Photometer Kit (includes the CAL CheckTM Standards) for the most economical option for testing.
Each HI97104C is supplied with:
- Sample cuvette (2 pcs.)
- Sample cap (2 pcs.)
- Plastic stopper (2 pcs.)
- A ZERO ‑ CAL CheckTM Cuvette A
- HI97701B ‑ CAL CheckTM Cuvette B for Free and Total Chlorine (Powder & Liquid)
- HI97710B ‑ CAL CheckTM Cuvette B for pH
- HI97722B ‑ CAL CheckTM Cuvette B for Cyanuric Acid
- HI97775B ‑ CAL CheckTM Cuvette B for Alkalinity
- Cloth for wiping cuvettes
- Scissors
- Alkaline batteries: 1.5V AA (3 pcs.)
- Instruction manual
- Meter quality certificate
- CAL CheckTM standard certificate
Reagent Sets
HI775-26 | Alkalinity Reagent - 25 tests |
HI93701-01 | Free Chlorine Reagent - 100 tests (powder) |
HI93701-03 | Free Chlorine Reagent - 300 tests (powder) |
HI93701-F | Free Chlorine Reagent - 300 tests (liquid) |
HI93701-T | Total Chlorine Reagent - 300 tests (liquid) |
HI93710-01 | pH Reagent - 100 tests |
HI93710-03 | pH Reagent - 300 tests |
HI93711-01 | Total Chlorine Reagent - 100 tests (powder) |
HI93711-03 | Total Chlorine Reagent - 300 tests (powder) |
HI93755-53 | Chlorine Removal Reagent |
HI93722-01 | Cyanuric Acid Reagent - 100 tests |
HI93722-03 | Cyanuric Acid Reagent - 300 tests |
Resources
-
Specifications
Specification Name Detail sku HI97104 Chlorine, Free & Total Range 0.00 to 5.00 mg/L (ppm) Chlorine, Free & Total Resolution 0.01 mg/L Chlorine, Free & Total Accuracy ±0.03 mg/L (ppm) ±3% of reading Chlorine, Free & Total Method Adaptation of US EPA method 330.5, DPD Colorimetric method Cyanuric Acid Range 0 to 80 mg/L (ppm) Cyanuric Acid Resolution 1 mg/L Cyanuric Acid Accuracy ±1 mg/L ±15% of reading Cyanuric Acid Method adaptation of the turbidimetric method pH Range 6.5 to 8.5 pH pH Resolution 0.1 pH pH Accuracy ±0.1 pH pH Method Phenol Red method Light Source light emitting diode Light Detector silicon photocell Bandpass Filter Bandwidth 8 nm Bandpass Filter Wavelength Accuracy ±1.0 nm Logging 50 readings (auto logging) Auto-off After 15 minutes of inactivity (30 minutes before a READ measurement) Environment 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non‑serviceable Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0") Weight 380 g (13.4 oz.) Warranty 2 years - Product Manuals