Pump Calibration Solution for Formol Number Mini Titrator
$27.00The HI84433 incorporates a peristaltic pump dosing system which allows for a highly accurate determination of the amount of titrant used. The HI84433-55M is a pump calibration standard that is used to calibrate the dosing system. A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The pump calibration procedure should be performed anytime the titrant or pH electrode is replaced. Routine calibration is recommended to ensure the highest accuracy when performing a titration.
- Pre-measured solution
- Clearly marked expiration date and lot number
- Air tight bottle with tamper-proof seal to ensure quality
Thank you for your interest in our products. A representative will contact you within the next business day.
The HI84433-55M is a 100 mL bottle of pump calibration standard solution that is used to calibrate the dosing system of the HI84433 mini titrator.
The content of amino acids and other nitrogen compounds in wine or fruit juice is determined by an acid-base titration to a fixed pH endpoint and expressed as total assimilable nitrogen. The determination of formol number is possible only after neutralization of the titratable acids present by a pH adjustment with HI84433-51 reagent, followed by the blockage of the amino groups by reaction with the HI84433-60 formol base reagent. The titration is then performed with the HI84433-50 titrant solution.
Formol number of wine and fruit juice, as performed on the HI84433 mini titrator, utilizes a simple sample preparation, a high-quality titrant dosing pump, potentiometric endpoint detection, and automatic computations. To maintain the high precision of the titrator, a simple pump calibration procedure is required. To achieve precise results, the instrument occasionally requires a pump recalibration. The pump calibration involves the analysis of a known volume of a known solution and compensates for changes in pump dosing that may occur due to many factors including tube stretching or aging. This procedure should be performed regularly with the HI84433-55M pump calibration solution to accurately determine the formol number of wines and fruit juices.
Replacement reagents required to operate the HI84433:
Range - 70.0 to 1400.0 mg/L as N | |
Pump calibration standard | HI84433-55M |
Titrant solution | HI84433-50 |
pH adjustment reagent | HI84433-51 |
Formol base reagent | HI84433-60 |
Additional reagent | HI84433-58 |