Our Swimming Pool and Spa Controllers are certified by Intertek to NSF/ANSI Standard 50. Pool and spa maintenance is necessary and keeping your water balanced, clean, and safe is a top priority. Performing regular water quality checks can be a hassle, but it doesn’t have to be when you automate your testing with our Swimming Pool and Spa Controllers.
Perfect for the disinfection and treatment of water in swimming pools, spas, and cold plunges. Monitor and control pH and free chlorine efficiently with our controllers.
Why choose Hanna Instruments Swimming Pool and Spa Controllers?
Accurate and reliable. Precisely control pH and free chlorine to ensure pool and spa water quality
Simple and convenient. Regulate pool and spa water automatically and reduce time spent on maintenance
Durable and compact. Built to meet the demands of pool and spa water quality testing and fits seamlessly into any environment with its small footprint

Who are Swimming Pool and Spa Controllers ideal for?
|
|
Product Disclaimer:
For your safety, we recommend that this product be installed by a qualified pool professional or licensed electrician in accordance with state requirements or local zoning regulations. Improper installation could cause dangerous electrical hazards resulting in serious injury or damage to the equipment or property.
See how your pool, spa, or cold plunge is doing from wherever you are. Monitor your controller remotely and securely from your phone, tablet, or laptop. Track your results by logging into your Hanna Cloud account.
View real-time readings, data trends, and a detailed history of results. Easily review your controller settings, alarm, and pump statuses.
Ensure that the treatment of your pool, spa, or cold plunge water is going swimmingly. Connect multiple devices and adjust your preferences to receive email or pop up messages with progress updates.

| Option 1: In-line mounting kit | Option 2: Flow cell mounting kit |
| Swimming Pool and Spa Controller | Swimming Pool and Spa Controller |
| Digital Multiparameter pH/ORP/Temperature Electrode (HI1036-1802) | Digital Multiparameter pH/ORP/Temperature Electrode (HI1036-1802) |
| Electrode fittings | Panel-mounted flow cell |
| Electrode saddle, Ø 50 mm pipe (1 pc.) | Flow cell connection valve with fittings and tubing 10 m |
| Injector (2 pcs.) | Valve saddle, Ø 50 mm pipe (2 pcs.) |
| Injectors saddle, Ø 50 mm pipe (2 pcs.) | Injector (2 pcs.) |
| Peristaltic pump tubing (2 pcs.) | Injector saddle, Ø 50 mm pipe (2 pcs.) |
| PVC aspiration and injection tubing, 10 m | Peristaltic pump tubing (2 pcs.) |
| Aspiration filter (2 pcs.) | PVC aspiration and injection tubing, 10 m |
| 4.01 and 7.01 pH buffer solutions (3 sachets of each) | 4.01 and 7.01 pH buffer solutions (3 sachets of each) |
| 470 mV ORP test solution (3 sachets) | 470 mV ORP test solution (3 sachets) |
| Power cable | Power Cable |
| Probe and instrument quality certificates | Probe and instrument quality certificates |
| Quick reference guide with QR code for manual download | Quick reference guide with QR code for manual download |
| Specification | Detail |
|---|---|
| SKU | BL12X Series |
| pH Range | 0.00 to 14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy (@25°C/77°F) | ±0.05 pH |
| pH Dosing | proportional with adjustable set point and proportional band delay to start at power-on and overdosing protection |
| ORP Range | ±2000 mV |
| ORP Resolution | 1 mV |
| ORP Accuracy (@25°C/77°F) | ±5 mV |
| ORP Dosing | proportional with adjustable set point and proportional band delay to start at power-on and overdosing protection pH dosing interlocked |
| Temperature Range | -5.0 to 105.0°C (23.0 to 221.0°F) |
| Temperature Resolution | 0.1°C (0.1°F) |
| Temperature Accuracy (@25°C/77°F) | ±1°C (±1.8°F) |
| Temperature Compensation | automatic, -5.0 to 105.0°C (23.0 to 221.0°F) for pH |
| Calibration | pH buffer calibration: automatic, two-point (4.01, 7.01, 10.01 pH) pH process calibration: one-point, manual input |
| Pump Control | automatic and manual modes adjustable flow rate from 0.5 to 3.5 L/h |
| Log Feature | automatic logging of pH, ORP, and temperature measurements, GLP and events including alarms, errors, and power failure capacity for 60 days with 10 second sampling interval all data .csv files are transferred by USB flash drive |
| Cloud connectivity with BL122 and BL123 only | Connect to Hanna Cloud using a secured connection. The instrument will send status information to the Hanna Cloud with a defined period (Readings: pH / ORP / Temperature, Events: Alarms / Warnings / Errors, Peripheral status: LEDs, Last dosed acid and chlorine volumes, GLP info). The instrument will send setup information to Hanna Cloud at startup and whenever the setup is changed on the instrument (Alarm, dosing, and general settings as well as system information). The 'Remote Hold' mode is an emergency mode that can be remotely triggered via web application. In this mode, the pumps are deactivated and can be cancelled manually from the controller menu. |
| Ethernet input for BL122 and BL123 only | Ethernet connector (RJ-45) 10/100 Mbps connection |
| Alarms | high and low with enable/disable option for all parameters alarm is triggered after 5 consecutive readings are over/under threshold |
| Alarm System | intuitive alert system based on LEDs alarm filtering options alarm relay control based on user setup |
| Password Protection | setup, calibration, and log recall options features are password protected |
| Connectivity | USB |
| GLP | pH/ORP calibration information including date and time for pH/ORP sensors |
| Alarm Relay Output | SPDT 5A/230 VAC activated by selectable pH/ORP/temperature selectable alarm conditions |
| Analog Outputs with BL121 and BL123 only | 4 to 20 mA, sourcing, configurable output impedance ≤ 500 Ohm accuracy < 0.5 % FS galvanically isolated up to 50 V relative to earth ground |
| Auxiliary Inputs | low level in acid/base tank (contact open) low level in chlorine tank (contact open) hold input (contact open) |
| Digital Probe Input | galvanic isolated digital input HI1036-1802 pH/ORP/temperature/matching pin combined probe with DIN waterproof connector |
| Power Supply | 100 — 240 VAC |
| Power Consumption | 10 VA |
| Environment | 0 to 50°C (32-122°F) max 95% RH non-condensing |
| Dimensions | 245 x 188 x 55 mm (73 mm with pumps) 9.6 x 7.4 x 2.2in. (2.9in. with pumps) |
| Weight | 1700 g (60 oz.) |