Our Swimming Pool and Spa Controllers are just what every business needs. Pool and spa maintenance is necessary and keeping your water balanced, clean, and safe is top priority. Performing regular water quality checks can be a hassle, but it doesn’t have to be when you automate your testing with our Swimming Pool and Spa Controllers.
Perfect for the disinfection and treatment of water in swimming pools, spas, and hot tubs. Monitor and control pH and Free Chlorine efficiently by adding this controller to your commercial facility.
Accurate and reliable. Precisely control pH and Free Chlorine to ensure pool and spa water quality
Simple and convenient. Regulate pool and spa water automatically and reduce time spent on maintenance
Durable and compact. Built to meet the demands of pool and spa water quality testing and fits seamlessly into any environment
*Products classified as Dangerous Goods can only be shipped via ground.
Our Swimming Pool and Spa Controllers are ideal for:
| |
Product Disclaimer:
For your safety, we recommend that this product be installed by a qualified pool professional or licensed electrician in accordance with state requirements or local zoning regulations. Improper installation could cause dangerous electrical hazards resulting in serious injury or damage to the equipment or property.
Manufactured with two peristaltic dosing pumps with replaceable chemical resistant tubing |
One of these pumps doses acid or base while the other is used to dose chlorine |
Alternatively, when a system uses a diaphragm pump, chlorine gas that forms from outgassing can collect in the pump head and cause the pump to lose its prime. With our Swimming Pool and Spa Controllers, the buildup of chlorine gas is not an issue due to the peristaltic pumps |
Made with proportionally controlled dosing pumps |
Allows precise control and helps maintain the desired set point |
Users can set the proportional band based on the amount of chemicals added and the size of the body of water being treated. For example, a large body of water like a swimming pool, should use a small proportional band (e.g., 0.1 pH) to ensure that the pumps dose more often when the reading nears the set point. On the other hand, with a small body of water such as a hot tub, it is better to set a larger proportional band (e.g., 1.0 pH). This minimizes the amount of time that the dosing pump is on for and this also avoids large swings in pH and ORP levels |
Dosing pump flow rate is adjustable from 0.5 to 3.5L/h |
The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point |
Larger bodies of water like swimming pools, require more chemicals to see a change in the reading compared to smaller bodies of water like hot tubs. This is where the adjustable flow rate comes in handy |
Perfect for chlorine disinfection as there is an inverse relationship between pH and ORP. When pH levels increase, the ORP levels decrease |
The dosing consent feature will not dose chlorine until the pH value is corrected first which can prevent a potentially irritating and unsafe condition |
This avoids having a chlorine concentration that is too high and prevents chemicals from being wasted |
Always know how your swimming pool, spa, or hot tub is doing from wherever you are. Check in on your controller remotely and securely from your phone, tablet, or laptop via the Hanna Cloud. All important information is sent to the Hanna Cloud via an Internet connection.
Get real-time readings and view all data including measurement trends, a results history log, controller settings, alarms, pump status, and more.
Ensure that the treatment of your spa, hot tub, or pool water is going swimmingly. Connect multiple devices and adjust your preferences to receive email or pop up messages with progress updates.
Got questions?Email us at sales@hannainst.com for assistance. We'd like to hear more about your requirements for your business. Let's chat and find the right solution for your testing needs. | |
Option 1: In-line mounting kit (BL120-10 and BL122-10) | Option 2: Flow cell mounting kit (BL120-20 and BL122-20) |
Digital Multiparameter pH/ORP/Temperature Electrode (HI1036-1802) | Digital Multiparameter pH/ORP/Temperature Electrode (HI1036-1802) |
Saddle for electrode, 50 mm pipe (1 pc.) | Panel mounted flow cell |
Fittings for electrode | Valve for flow cell connections with fittings and tubing (10 m) |
Injector (2 pcs.) | Injector (2 pcs.) |
Saddle for injectors, 50 mm pipe (2 pcs.) | Saddle for valves, 50 mm pipe (2 pcs.) |
Peristaltic pump tubing (2 pcs.) | Saddle for injectors, 50 mm pipe (2 pcs.) |
Aspiration and injection tubing (5+5 m) | Peristaltic pump tubing (2 pcs.) |
Aspiration filter (2 pcs.) | Aspiration and injection tubing (5+5 m) |
7.01 pH buffer solution (3 sachets) | Aspiration filter (2 pcs.) |
4.01 pH buffer solution (3 sachets) | 7.01 pH buffer solution (3 sachets) |
470 mV ORP test solution (3 sachets) | 4.01 pH buffer solution (3 sachets) |
Power cable | 4.70 mV ORP test solution (3 sachets) |
Instrument quality certificate | Power Cable |
Instruction manual | Instrument quality certificate |
Specification | Detail |
---|---|
SKU | BL12x No Analog Outputs |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy (@25°C/77°F) | ±0.05 pH |
pH Dosing | proportional with adjustable set point and proportional band delay to start at power-on and overdosing protection |
ORP Range | ±2000 mV |
ORP Resolution | 1 mV |
ORP Accuracy (@25°C/77°F) | ±5 mV |
ORP Dosing | proportional with adjustable set point and proportional band delay to start at power-on and overdosing protection pH dosing interlocked |
Temperature Range | -5.0 to 105.0°C (23.0 to 221.0°F) |
Temperature Resolution | 0.1°C (0.1°F) |
Temperature Accuracy (@25°C/77°F) | ±1°C (±1.8°F) |
Temperature Compensation | automatic, -5.0 to 105.0°C (23.0 to 221.0°F) for pH |
Calibration | pH buffer calibration: automatic, two-point (4.01, 7.01, 10.01 pH) pH process calibration: one-point, manual input |
Pump Control | automatic and manual modes adjustable flow rate from 0.5 to 3.5 L/h |
Log Feature | automatic logging of pH, ORP, and temperature measurements, GLP and events including alarms, errors and power failure capacity for 60 days with 10 second sampling interval all data .csv files are transferred by USB flash drive |
Cloud connectivity with BL123 and BL122 only | The BL122 can connect to Hanna Cloud using a secured connection. The instrument will send status information to the Hanna Cloud with a defined period (Readings: pH / ORP / Temperature, Events: Alarms / Warnings / Errors, Peripheral status: LEDs, Last dosed acid and chlorine volumes, GLP info). The instrument will send setup information to Hanna Cloud at startup and whenever the setup is changed on the instrument (Alarm, dosing, and general settings as well as system information). The 'Remote Hold' mode is an emergency mode that can be remotely triggered via web application. In this mode, the pumps are deactivated and can be cancelled manually from the controller menu. |
Ethernet input for BL123 and BL122 only | Ethernet connector (RJ-45) 10/100 Mbps connection |
Alarms | high and low with enable/disable option for all parameters alarm is triggered when 5 consecutive readings are over/under threshold |
Alarm System | intuitive alert system based on LEDs alarm filtering options alarm relay control based on user setup |
Password Protection | setup, calibration and log recall options features are password protected |
Connectivity | USB |
GLP | pH/ORP calibration information including date and time for pH/ORP sensors |
Alarm Relay Output | SPDT 5A/230 VAC activated by pH/ORP/temperature selectable alarm conditions |
Auxiliary Inputs | low level in acid/base tank (contact open) low level in chlorine tank (contact open) hold input (contact open) |
Digital Probe Input | galvanic isolated digital input HI1036-1802 pH/ORP/temperature/matching pin combined probe with DIN waterproof connector |
Power Supply | 100 — 240 VAC |
Power Consumption | 10 VA |
Environment | 0 to 50°C (32-122°F) max 95% RH non-condensing |
Dimensions | 245 x 188 x 55 mm (73 mm with pumps) 9.6 x 7.4 x 2.2in. (2.9in. with pumps) |
Weight | 1700 g (60 oz.) |