The Wine Titrator is perfect for winemakers who need accurate results, ease-of-use, and the ability to expand the system as their analytical needs grow. It comes preloaded with methods for wine analysis, and with Hanna, you get the support you need to run them perfectly in your lab. Titrate for a variety of measurements including pH, Total Acidity, Free & Total Sulfur Dioxide, Formol Number, Volatile Acids, Reducing Sugars, and many more.
The Wine Titrator is perfect for winemakers who need accurate results, ease-of-use, and the ability to expand the system as their analytical needs grow. It comes preloaded with methods for wine analysis, and with Hanna, you get the support you need to run them perfectly in your lab.
Titrate for a variety of measurements including pH, Total Acidity, Free & Total Sulfur Dioxide, Formol Number, Volatile Acids, Reducing Sugars, and many more.
Hanna's Wine Titrator comes preloaded with methods for wine analysis, and with Hanna, you get the support you need to run them perfectly in your lab.
Supplied with a full suite of standard wine methods, the Wine Titrator is optimized for winemakers. Packages are designed so that you'll have everything you need to produce quality wine. Our preloaded packages include the following methods:
Titratable Acidity
Total SO2(AO)
Our exchangeable Clip Lock™ burette system helps you conveniently separate and switch between your reagents so you don't have to be concerned about cross-contamination.
Our unmatched 40,000 step piston-driven dosing pump is capable of dosing extremely small and highly accurate volumes of reagent, helping you achieve a very precise endpoint.
A dynamic dosing algorithm allows for timely and accurate titration results by providing larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.
Our large color display shows you everything you need to know during testing.
Our live titration curve helps you quickly recognize patterns and problems that may arise during your analysis.
Custom keys allow you to clearly navigate between screens so you don't get lost.
Final reports are customizable so you can make sure you are viewing and storing your most important information.
Our software allows you to record full GLP (Good Laboratory Practice) data so there is no need to compromise the quality of your results.
Use our software or a USB to conveniently transfer files between your titrator and computer.
You can print reports directly from the titrator with a connected printer and conveniently view results with a connected monitor.
Connect the devices that help you most, whether it be an analytical balance for automatic sample entry or a printer for your reports.
Specification | Detail |
---|---|
sku | HI901W-01 |
pH range | -2.0 to 20.0 pH -2.00 to 20.00 pH -2.000 to 20.000 pH |
pH Resolution | 0.1 0.01 0.001 pH |
pH Accuracy (@25ºC/77ºF) | ±0.001 pH |
pH Calibration | up to five-point calibration, eight standard buffers and five custom buffers |
mV Range | -2000.0 to 2000.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy (@25ºC/77ºF) | ±0.1 mV |
mV Calibration | single-point offset |
ISE Range | 1¢10»¶ to 9.99¢10¹° |
ISE Resolution | 1 0.1 0.01 |
ISE Accuracy | ±0.5% monovalent ±1% divalent |
ISE Calibration | up to five-point calibration, seven standard solutions and five user-defined standards |
Temperature Range | -5.0 to 105.0°C 23.0 to 221.0°F 268.2 to 378.2K |
Temperature Resolution | 0.1°C 0.1°F 0.1K |
Temperature Accuracy | ±0.1°C ±0.2°F ±0.1K, excluding probe error |
Temperature Compensation | manual (MTC) or automatic (ATC) |
Programmable Stirrer | overhead propeller type, 200 to 2500 rpm, resolution 100 rpm |
Display | 5.7in. (320 x 240 pixel) backlit color LCD |
Burette Sizes | 5, 10, 25, and 50 mL |
Burette Resolution | 1/40000 |
Display Resolution | 0.001 mL |
Dosing Accuracy | ±0.1% of full burette volume |
Methods | up to 100 methods (standard and user-defined) |
Logging Data | up to 100 titration and pH/mV/ISE reports |
Burette Auto-Detection | burette size is automatically recognized when inserted into the unit |
Flow Rate | user-selectable from 0.1 mL/min to 2 x burette volume/min |
Endpoint Determination | single equivalence point (1st or 2nd derivative) or fixed pH/mV value |
Potentiometric Titrations | acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric |
Measurement Units | user-specified expression of concentration units to suit specific calculation requirements |
Real-Time & Stored Graphs | mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve pH mode, mV mode or ISE mode: pH/mV/concentration versus time |
USB Host (Side) | flash drive compatibility for transfer of methods and reports |
Peripherals (Rear) | connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232 |
GLP Conformity | instrumentation data storage and printing capabilities |
Languages | English, Portuguese, Spanish |
Operating Environment | 10 to 40°C (50 to 104°F), up to 95% RH |
Storage Environment | -20 to 70°C (-4 to 158°F), up to 95% RH |
Power Supply | 100-240 VAC -01 models, US plug (type A) -02 models, European plug (type C) |
Dimensions | 390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in) |
Weight | approximately 9 kg (20 lbs.) (with one pump, stirrer and sensors) |
Ordering Information | HI901W includes titrator with one analog board, overhead propeller stirrer with stand, 25 mL glass burette, dosing pump, temperature sensor, USB cable, 256 MB USB flash drive and PC software. |
Warranty | 2 years |