Accurate and easy to use, the HI981045 pH Tester is ideal for pH measurement during meat processing and is designed to be used with FC097, a high-grade stainless-steel blade. The FC097 blade is sold separately.
The tester is compatible with the separately-sold FC097 removable meat blade accessory (with o-ring). The design features a 25-mm (0.98") blade-cutout opening for direct contact with the sample. This design is suitable for processes that need to comply with food-hygiene and Hazard Analysis Critical Control (HACCP) regulations.
The conical tip design allows for easy penetration into solids and semisolids, which is needed when wanting to take a direct measurement in meat.
The pH electrode has an outer junction sleeve that can be removed and cleaned. Once cleaned a small amount of supplied gel electrolyte is added and the junction is refreshed improving the pH measurement and extending the life of the meter.
Polyvinylidene Fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength, and resistance to ultraviolet light. PVDF is also resistant to fungal growth.
The pH glass tip uses a special LT glass formulation suited for fast stabilization and accurate results at lower temperatures in order to have the ideal resistance for the measuring circuit.
An enhanced LCD displays the measurement reading, stability indicator, low battery indicator, and calibration tags.
These testers are calibrated automatically to one or two points. The calibration buffers are automatically recognized and after calibration the buffer values used are shown on the display.
An hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes, the indicator disappears and a reading can be taken.
These testers can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the tester is left on. The auto-off feature can also be disabled.
During calibration the meter will display an error (Err) message as an indicator that the probe needs to be cleaned.
These testers have an exceptional battery life of approximately 800 hours. When the battery power is running low, the low battery indicator blinks.
Specification | Detail |
---|---|
SKU | HI981045 |
pH Ranges | 0.00 to 12.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy (@25°C/77°F) | ±0.05 pH |
pH Calibration | Automatic, one or two-point |
pH Temperature Compensation | Automatic, 0 to 50°C (32 to 122°F) |
Automatic Shut-Off | 8 minutes, 60 minutes, or disabled |
Battery Type / Life | CR2032 Li-ion / approx. 800 hours of continuous use |
Environment | 0 to 50°C (32 to 122°F) RH 95% max |
Dimensions | 51 x 148 x 21 mm (2 x 5.8 x 0.9) |
Weight | 45 g (1.58 oz.) |
Ordering Information | HI981045 (with thread) is supplied with pH 4.01 buffer solution, 20 mL sachet (2 pcs.), pH 7.01 buffer solution, 20 mL sachet (2 pcs.), electrode cleaning solution for meat, grease, and fats, 20 mL sachet (2 pcs.), electrode storage solution, 13 mL dropper bottle, gelled bridge electrolyte, 13 mL dropper bottle, 3V Lithium battery – CR2032, instrument quality certificate, and instruction manual. |
Warranty | 1 year |