Multiparameter Benchtop Photometer and pH meter
$1,299.99HI83300 is a compact, multiparameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. To save valuable laboratory benchtop space, the HI83300 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.
- Advanced optical system
- Unparalleled performance from a benchtop photometer
- Digital pH electrode input
- Save valuable bench space with one meter that works both as a photometer and as a laboratory pH meter
- Absorbance measuring mode
- Allows performance verification using CAL CheckTM standards
Thank you for your interest in our products. A representative will contact you within the next business day.
A digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.
The HI83300 offers an absorbance measuring mode that allows for CAL CheckTM standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.
Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.
Please note, reagents are not included and can be purchased here.
Features and Benefits
Digital pH Electrode Input
- Measure pH and temperature with a single probe
- Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability
- pH CAL CheckTM alerts user to potential problems during the calibration process
- Space saving having a pH meter and photometer built into one meter
Data Logging
- Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button
- Sample ID and User ID information can be added to a logged reading using alphanumeric keypad
Connectivity
- Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port
- Data is exported as a .CSV file for use with common spreadsheet programs
Battery Status Indicator
- Indicates the amount of battery life left
Error Messages
- Photometric error messages include no cap, high zero, and standard too low
- pH calibration messages include clean electrode, check buffer and check probe
Backlit 128 x 64 Pixel Graphic LCD Display
- Backlit graphic display allows for easy viewing in low light conditions
- The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter
Built-in Reaction Timer for Photometric Measurements
The measurement is taken after the countdown timer expires.
Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements
Absorbance mode
- Hanna's exclusive CAL CheckTM cuvettes for validation of light source and detector
- Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry
Units of Measure
- Appropriate unit of measure along with chemical form is displayed along with reading
Result Conversion
- Automatically convert readings to other chemical forms with the touch of a button
Cuvette Cover
- Aids in preventing stray light from affecting measurements
On-Screen Features
Advanced Optical System
-
Parameters
Parameter Range Resolution Accuracy (at 25 °C) Method Wavelength Reagent Code Absorbance 0.000 to 4.000 Abs 0.001 Abs +/-0.003Abs @ 1.000 Abs Alkalinity 0 to 500 mg/L (as CaCO3 ) 1 mg/L ±5 mg/L ±5% of reading Colorimetric Method 610 nm HI775-26 Alkalinity, Marine 0 to 300 mg/L (as CaCO3 ) 1 mg/L ±5 mg/L ±5% of reading Colorimetric Method 610 nm HI755-26 Aluminum 0.00 to 1.00 mg/L (as Al3+) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the aluminon method. 525 nm HI93712-01 Ammonia, Low Range 0.00 to 3.00 mg/L (as NH3 -N) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method. 420 nm HI93700-01 Ammonia, Medium Range 0.00 to10.00 mg/L (as NH3-N) 0.01 mg/L ±0.05 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93715-01 Ammonia, High Range 0.0 to 100.0 mg/L (as NH3 -N) 0.1 mg/L ±0.5 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93733-01 Bromine 0.00 to 8.00 mg/L (as Br2 ) 0.01 mg/L ±0.08 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method 525 nm HI93716-01 Calcium 0 to 400 mg/L (as Ca2+) 1 mg/L ±10 mg/L ±5% of reading Adaptation of the Oxalate method 466nm HI937521-01 Calclium, Marine 200 to 600 mg/L (as Ca2+) 1 mg/L ±6% of reading Adaptation of the Zincon method 610 nm HI758-26 Chloride 0.0 to 20.0 mg/L (as Cl) 0.1 mg/L ±0.5 mg/L ±6% of reading Adaptation of the mercury(II) thiocyanate method 466 nm HI93753-01 Chlorine Dioxide 0.00 to 2.00 mg/L (as ClO2 ) 0.01 mg/L ±0.10 mg/L ±5% of reading Adaptation of the Chlorophenol Red method 575 nm HI93738-01 Chlorine Dioxide, Rapid Method 0.00 to 2.00 mg/L (as ClO2 ) 0.01 mg/L ±0.10 mg/L ±5% of reading Adapted from Standard Methods for the Examination of Water and Wastewater,18 ed., 4500 ClO2 D. 525 nm HI96779-01 Chlorine, Free 0.00 to 5.00 mg/L (as Cl2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93701-01 Chlorine, Free Ultra Low Range 0.000 to 0.500 mg/L (as Cl2 ) 0.001 mg/ ±0.020 mg/L ±3% of reading Adaptation of the Standard Method 4500-Cl G 525 nm HI95762-01 Chlorine, Total 0.00 to 5.00 mg/L (as Cl2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93711-01 Chlorine, Total Ultra Low Range 0.000 to 0.500 mg/L (as Cl2 ) 0.001 mg/L ±0.020 mg/L ±3% of reading Adaptation of the EPA recommended Method 330.5 525 nm HI95761-01 Chlorine, Total Ultra High Range 0 to 500 mg/L (as Cl2 ) 1 mg/L ±3 mg/L ±3% of reading Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl 525 nm HI95771-01 Chromium (VI), Low Range 0 to 300 µg/L (as Cr(VI)) 1 µg/L ±10 µg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method 525 nm HI93749-01 Chromium (VI), High Range 0 to 1000 µg/L (as Cr(VI)) 1 µg/L ±5 µg/L ±4% of reading at 25 °C Adaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method 525 nm HI93723-01 Color of Water 0 to 500 PCU (Platinum Cobalt Units) 1 PCU ±10 PCU ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method 420 nm Copper, Low Range 0.000 to 1.500 mg/L (as Cu) 0.001 mg/L ±0.010 mg/L ±5% of reading Adaptation of the EPA method 575 nm HI95747-01 Copper, High Range 0.00 to 5.00 mg/L (as Cu) 0.01 mg/L ±0.02 mg/L ±4% of reading Adaptation of the EPA method 575 nm HI93702-01 Cyanuric Acid 0 to 80 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading Adaptation of the turbidimetric method 525 nm HI93722-01 Fluoride, Low Range 0.00 to 2.00 mg/L (as F) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method 575 nm HI93729-01 Fluoride, High Range 0.0 to 20.0 mg/L (as F) 0.1 mg/L ±0.5 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method 575 nm HI93739-01 Hardness, Calcium 0.00 to 2.70 mg/L (as CaCO3 ) 0.01 mg/L ±0.11 mg/L ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method 525 nm HI93720-01 Hardness, Magensium 0.00 to 2.00 mg/L (CaCO3 ) 0.01 mg/L ±0.11 mg/L ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method 525 nm HI93719-01 Hardness, Total Low Range 0 to 250 mg/L (as CaCO3 ) 1 mg/L ±5 mg/L ±4% of reading Adaptation of the EPA recommended method 130.1 466 nm HI93735-00 Hardness, Total Medium Range 200 to 500 mg/L (as CaCO3 ) 1 mg/L ±7 mg/L ±3% of reading Adaptation of the EPA recommended method 130.1 466 nm HI93735-01 Hardness, Total High Range 400 to 750 mg/L (as CaCO3 ) 1 mg/L ±10 mg/L ±2% of reading Adaptation of the EPA recommended method 130.1 466 nm HI93735-02 Hydrazine 0 to 400 µg/L (as N2H4 ) 1 µg/L ±4% of full scale reading Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method 466 nm HI93704-01 Iodine 0.0 to 12.5 mg/L (as I2 ) 0.1 mg/L ±0.1 mg/L ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method 525 nm HI93718-01 Iron, Low Range 0.000 to 1.600 mg/L (as Fe) 0.001 mg/L ±0.010 mg/L ±8% of reading Adaptation of the TPTZ Method 575 nm HI93746-01 Iron, High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters 525 nm HI93721-01 Iron (II) - Ferrous 0.00 to 6.00 mg/L Fe2+ ) 0.01 mg/L ±0.10 mg/L ±2% of reading Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method 525 nm HI96776-01 Iron (II & III) – Ferrous & Ferric 0.00 to 6.00 mg/L Fe 0.01 mg/L ±0.10 mg/L ±2% of reading Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method 525 nm HI96777-01 Magnesium 0 to 150 mg/L (as Mg2+) 1 mg/L ±5 mg/L ±3% of reading Adaptation of the Calmagite method 466 nm HI937520-01 Manganese, Low Range 0 to 300 µg/L (as Mn) 1 µg/L ±10 µg/L ±3% of reading Adaptation of the PAN Method 575 nm HI93748-01 Manganese, High Range 0.0 to 20.0 mg/L (as Mn) 0.1 mg/L ±0.2 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method 525 nm HI93709-01 Molybdenum 0.0 to 40.0 mg/L (as Mo6+) 0.1 mg/L ±0.3 mg/L ±5% of reading Adaptation of the mercaptoacetic acid method 420 nm HI93730-01 Nickel, Low Range 0.000 to 1.000 mg/L (as Ni) 0.001 mg/L ±0.010 mg/L ±7% of reading Adaptation of the PAN method 575 nm HI93740-01 Nickel, High Range 0.00 to 7.00 g/L (as Ni) 0.01 g/L ±0.07g/L ±4% of reading Adaptation of the photometric method 575 nm HI93726-01 Nitrate 0.0 to 30.0 mg/L (as NO3 - N) 0.1 mg/L ±0.5 mg/L ±10% of reading Adaptation of the cadmium reduction method 525 nm HI93728-01 Nitrite, Marine Ultra Low Range 0 to 200 µg/L (as N02 -N) 1 µg/L ±10 µg/L ±4% of reading Adaptation of the EPA Diazotization method 354.1 466 nm HI764-25 Nitrie, Low Range 0 to 600 µg/L (as NO2 -N) 1 µg/L ±20 µg/L ±4% of reading Adaptation of the EPA Diazotization method 354.1 466 nm HI93707-01 Nitrite, High Range 0 to 150 mg/L (as NO2-) 1 mg/L ±4 mg/L ±4% of reading Adaptation of the Ferrous Sulfate method 575 nm HI93708-01 Oxygen, Dissolved 0.0 to 10.0 mg/L (as O2 ) 0.1 mg/L ±0.4 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method 420 nm HI93732-01 Oxygen Scavengers (Carbohydrazide) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.01 mg/L ±0.02 mg/L ±3% of reading Adaptation of the iron reduction method 575 nm HI96773-01 Oxygen Scavengers (Diethylhydroxylamine)(DEHA) 0 to 1000 µg/L (as DEHA) 1 µg/L ±5 µg/L ±5% of reading Adaptation of the iron reduction method 575 nm HI96773-01 Oxygen Scavengers (Hydroquinone) 0.00 to 2.50 mg/L (as Hydroquinone) 0.01 mg/L ±0.04 mg/L ±3% of reading Adaptation of the iron reduction method 575 nm HI96773-01 Oxygen Scavengers (Iso-ascorbic Acid) 0.00 to 4.50 mg/L (as Iso-ascorbic acid) 0.01 mg/L ±0.03 mg/L ±3 % of reading Adaptation of the iron reduction method 575 nm HI96773-01 Ozone 0.00 to 2.00 mg/L (as O3 ) 0.01 mg/L ±0.02 mg/L ±3% of reading Colorimetric DPD Method 525 nm HI93757-01 pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH Adaptation of the Phenol Red method 525 nm HI93710-01 Phosphate, Marine Ultr Low Range 0 to 200 µg/L (as P) 1 µg/L ±5 µg/L ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method 610 nm HI736-25 Phosphate, Low Range 0.00 to 2.50 mg/L (as PO4 3-) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the Ascorbic Acid method 610 nm HI93713-01 Phosphate, High Range 0.0 to 30.0 mg/L(as PO43-) 0.1 mg/L ±1.0 mg/L ±4% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method 525 nm HI93717-01 Potassium 0.0 to 20.0 mg/L (as K) 0.1 mg/L ±3.0 mg/L ±7% of reading Adaptation of the Turbidimetric Tetraphenylborate method 466 nm HI93750-01 Silica, Low Range 0.00 to 2.00 mg/L (as SiO2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method 610 nm HI93705-01 Silica, High Range 0 to 200 mg/L (as SiO2 ) 1 mg/L ±1 mg/L ±5% of reading Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO2 466 nm HI96770-01 Silver 0.000 to 1.000 mg/L (as Ag) 0.001 mg/L ±0.020 mg/L ±5% of reading Adaptation of the PAN method 575 nm HI93737-01 Sulfate 0 to 150 mg/L (as SO42-) 1 mg/L ±5 mg/L ±3% of reading Sulfate is precipitated with barium chloride crystals 466 nm HI93751-01 Surfactants, Anionic 0.00 to 3.50 mg/L (as SDBS) 0.01 mg/L ±0.04 mg/L ±3% of reading Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS 610 nm HI95769-01 Zinc 0.00 to 3.00 mg/L (as Zn) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method 575 nm HI93731-01
Resources
-
Specifications
Specification Name Detail sku HI83300-01 Wavelength Accuracy ±1 nm Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters Spectral bandwidth 8 nm Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode digital pH electrode (not included) Logging Type log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity GLP calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Battery Type / Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Environment 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8") Weight 1.0 kg (2.2 lbs.) Photometer/Colorimeter Light Detector silicon photodetector Cuvette Type round, 24.6 mm Number of Methods 128 max. Ordering Information Supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. Warranty 2 years Note *Reagents are not included. - Product Manuals