Panel-mounted pH Analog Indicator with Self Diagnostic Test
$599.99HI8510 is a panel-mounted pH indicator designed for simplicity of use in a wide range of industrial process applications. Designed for easy and fast installation, the HI 8510 is provided with membrane keypads on the front panel, large display, and auto-diagnostic functions to check pH electrode and instrument status.
- Automatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations.
- Displays values on the easy to read LCD.
- A removable, transparent splash-proof cover protects the front panel.
Thank you for your interest in our products. A representative will contact you within the next business day.
Easy Installation
HI 8510 is provided with membrane keypads on the front panel, large display, and auto-diagnostic functions to check pH electrode and instrument status.
Easy pH Electrode Connection
Allows for quick and easy connection to any pH meter or transmitter.
Self-testing Diagnostics
Built-in autodiagnostic functions to enable the user to check and troubleshoot any malfunctions. The functions are made via front panel keys to isolate the cause of malfunction whether it is due to pH electrode contamination, internal offset circuit or the amplifier circuit.
Protective Cover
A removable, transparent splash-proof cover protects the front panel.
Recorder Terminals
To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a copy of the results on demand.
Automatic Temperature Compensation
A 2-wire Pt100 can be connected to provide automatic temperature compensation of measurements.
Resources
-
Specifications
Specification Name Detail sku HI8510 pH Range 0.00 to 14.00 pH pH Resolution 0.01 pH pH Accuracy (@20°C/68°F) ±0.02 pH (0 to 100 °C)/ ±0.05 pH (-20 to 0 °C) (electrode); ±0.5% (transmitter) Temperature Compensation Fixed or automatic with Pt100 from ‑20 to 100 °C (‑4 to 212 °F) Calibration Offset: ±2 pH with OFFSET trimmer;Slope: 80 to 110% with SLOPE trimmer Recorder Output 0‑20 mA or 4‑20 mA (isolated) Power Output ±5 Vcc; 150 mA max load for amplified electrodes Backlight Continuous ON Power Supply 115 or 230 Vac; 60/50 Hz Environment $-10 to 50°C (14 to 122°F); RH max 95% non-condensing Enclosure/ Case Material Black anodized aluminium body; front and back with ABS; transparent splash-proof front cover Dimensions 141 x 69 mm (5.6 x 2.7'') Weight kg (2.2 lb.) - Product Manuals