Set yourself up for testing success with our pH/ORP/ISE and EC/TDS and DO Benchtop Meter Starter Kit (HI6553). There are two options available to choose from, our opdo® kit which includes an opdo® probe or our DO kit which includes a polarographic DO probe. Our high-performing benchtop meter is ready-to-use straight out of the box and is fully equipped with everything you need to test. Includes necessary modules, electrodes, solutions, and more.
Fits seamlessly into any laboratory or industry environment.
Perfect for chemists, researchers, educators, food manufacturers, beverage producers, and metal finishers to name a few.
Specification Name | Detail |
---|---|
Sku | HI6553 |
pH Range | -2.0 to 20.0 pH; -2.00 to 20.00 pH; - 2.000 to 20.000 pH |
pH Resolution | 0.1 pH; 0.01 pH; 0.001 pH |
pH Accuracy | ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) |
Calibration Points | Up to 5 |
Calibration Type | Automatic; Semiautomatic; Manual |
Standard Buffers | Hanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) |
Custom Buffers | Up to 5 |
Custom Group | Option to select from eight standard buffers and user-defined custom buffers |
First Calibration Point | Offset or Point (user setting) |
Isopotential Point | -2.000 to 20.000 pH |
mV Range | -2000.0 to 2000.0 mV |
mV Resolution | 1 mV; 0.1 mV |
mV Accuracy | ±0.2 mV ±1 last significant digit |
mV Calibration | Single point offset, ±2000.0 mV |
ISE Range | 1.0×10¯5 to 300.0 ppt (g/L or mg/mL) 5.0×10¯3 to 1.0×105 ppm (mg/L or µg/mL) 1.0 to 5.0×107 ppb (µg/L) 1.0×10¯7 to 10.0 M (mol/L) 1.0×10¯4 to 1.0×104 mmol/L 1.0×10¯6 to 60.0 %w/v 5.0×10¯7 to 5.0×107 user |
ISE Resolution | 1, 2, 3 significant digits |
ISE Accuracy | ±0.5% (monovalent ions); ±1% (divalent ions) |
ISE Calibration Points | Up to 5 |
ISE Calibration Type | All Standards; Standard Group |
ISE Standards | 7 standard solutions available for each concentration unit |
ISE Custom Standards | Up to 5 |
ISE Custom Group | Up to 5 |
Conductivity Range | 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm |
Conductivity Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
Conductivity Accuracy | ±1 % of reading or ±0.010 μS/cm, whichever is greater |
Conductivity Cell Constant | 0.0500 to 200.0000 /cm |
Conductivity Calibration Type | Automatic; Manual |
Conductivity Calibration Points | Single; Up to 5 |
Conductivity Calibration Solutions | 84 μS/cm; 1413 μS/cm; 5000 μS/cm; 12880 μS/cm; 80000 μS/cm; 111800 μS/cm |
Resistivity Range | 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm |
Resistivity Resolution | 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm |
Resistivity Accuracy | ±1 % of reading or ±1 Ω•cm, whichever is greater |
Total Dissolved Solids (TDS) Range | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) |
Total Dissolved Solids (TDS) Resolution | 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt |
Total Dissolved Solids (TDS) Accuracy | ±1 % of reading or ±0.01 ppm, whichever is greater |
Salinity Range | 0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale) |
Salinity Resolution | 0.01 PSU; 0.01 ppt; 0.1 % |
Salinity Accuracy | ±1 % of reading |
Salinity Calibration | 1 point, using 100 % salinity calibration solution (% scale only) |
Salinity Compensation | Manual > 0.00 to 45.00 PSU or ppt > 0.0 to 130.0 % |
DO Range | 0.0 to 500.0 % saturation; 0.00 to 90.00 mg/L (ppm) concentration |
DO Resolution | 0.1 % saturation; 0.01 mg/L (ppm) |
DO Accuracy | Refer to probe used |
DO Calibration Points | One or two points at 100.0 % (8.26 mg/L) and 0.0 % (0.00 mg/L) |
DO Calibration Type | Automatic; Manual (user entered value in % saturation, mg/L, or ppm) |
Barometric Pressure Range | 450.0 to 850.0 mmHg; 600.0 to 1133.2 mbar; 60.00 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm |
Barometric Pressure Resolution | 0.1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm |
Barometric Pressure Accuracy | ±3 mmHg within ±15 % from calibration point; ±3 mmHg ±1 least significant digit |
Barometric Pressure Compensation | Automatic (meter-integrated barometer); Manual |
Temperature Range | −20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K |
Temperature Resolution | 0.1 °C; 0.1 °F; 0.1 K |
Temperature Accuracy | For pH and conductivity: ±0.2 °C; ±0.4 °F; ±0.2 K For DO: Refer to probe used |
Temperature Calibration | Single point, adjustable |
Temperature Compensation | For pH and DO: Automatic; Manual For Conductivity: Linear; Natural; Standard; Disabled |
Reference Temperature | For Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K) |
Temperature Coefficient | For Conductivity: 0.00 to 10.00 %/°C |
Reading Mode | Direct Direct/Autohold For ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction For Conductivity: Direct/USP For DO Only: OUR, SOUR, BOD |
Basic View | Measurement data; Measurement profile (if enabled); Stability status |
Simple GLP View | Basic view information For pH: Last calibration date, slope, offset (pH, Rel. mV - ISE only) For Conductivity: Last calibration date and offset For DO: Last calibration date, offset, average slope |
Full GLP View | Simple GLP Information; Calibration point details (pH, ISE, conductivity, salinity, and DO) |
Graph View | Basic view information; Measurement versus time graph |
Table View | Basic view information; Table with measurements updated every second |
Reading Stability Criteria | Accurate; Medium; Fast |
Reading Sampling Rate | 1000 ms |
Logging Type | Automatic; Manual; Autohold |
Logging Number of Records | 50,000 maximum per file and stores at least 1,000,000 data points per user |
Logging Automatic Interval | 1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes |
Logging Sample ID | Incremental Mode; Manual |
Logging Export Option | .CSV file format |
Connectivity USB-A | 2 ports keyboard and/or printer input USB Flash Drive |
Connectivity USB-C | 1 port PC Connectivity and USB-C Type Flash Drive |
Connectivity Wi-Fi & Ethernet | FTP; Web Server (Log transfer and download); Email |
Connectivity RS232 | Connecting peripherals |
Calibration Reminder | Daily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled |
Users | Up to 9 users and the default administrator account |
Power Supply | DC adapter 100-240 VAC to 24 VDC 2A |
Environment | 0 to 50 °C / 32 to 122 °F / 273 to 323 K maximum 95 % RH non-condensing |
Dimensions | 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 ") |
Weight | 8.05 lbs |
Up to 3 measurements can be shown on the benchtop screen at the same time. Various display configurations and formats are available and can be adjusted in settings.
Streamline sample handling with a Mini Magnetic Stirrer. This piece of testing equipment automatically stirs for you, so that you can focus on other important tasks. Easily control the stirring speed and rotation direction by adjusting the slider on the benchtop screen or using the knob located on the front of the stirrer. Two stirrers can be connected to the benchtop at the same time.
Integrating a Thermal Printer as part of the quality assurance process is required in certain laboratories. Plus, it is a nice-to-have for added convenience. With its compact size, this printer takes up minimal space, making it an ideal choice for a lab setting. This printer simply connects to our pH/ORP/ISE and EC/TDS and DO Benchtop Meter (HI6553). Quickly print and share data reports on the spot.
Got questions?
We'd like to hear more about your requirements and how we can create the best testing experience together.
|
![]() |